TELEMECANIQUE XXW54P3APL01DM6 — Diffuse Ultrasonic Sensors
Telemecanique XXW54P3APL01DM6: Ultrasonic sensor, Ø54 mm wide beam, 4–20 mA analog + PNP discrete output, 0.425–3 m range, Deutsch 6-pin connector.

Status: In production
Brand: Telemecanique
Product: Ultrasonic sensor, Ø54 mm wide beam, diffuse, 4–20 mA analog + PNP discrete output
Sensing range (Sd): 0.425–3 m
Output: 4–20 mA analog + PNP (1 NO or 1 NC, programmable)
Electrical connection: 0.15 m cable + Deutsch DTM04-6P
Rated supply voltage: 12–24 V DC
Degree of protection: IP65, IP67, IP69K
Telemecanique XXW54P3APL01DM6 is a diffuse, wide-beam ultrasonic sensor with a Ø54 mm body from the application series of the XX range. Its nominal sensing distance is 3 m, set by software with the configuration kit; the sensing range is 0.425–3 m and the blind zone 425 mm. It works at 48 kHz with a 50° beam angle, 0.1 % repeat accuracy and 20 mm maximum differential travel, and detects a Ø12 mm cylinder at 3 m. It provides a 4–20 mA analog output together with a programmable PNP discrete output (1 NO or 1 NC).
The current output drives up to 250 Ω at 12 V DC and up to 850 Ω at 24 V DC; the PNP output switches up to 100 mA; both outputs are overload and short-circuit protected. The reverse-polarity protected 12–24 V DC supply (9–32 V DC limits) draws 30 mA. It connects via a Deutsch DTM04-6P male connector on a 0.15 m cable; joining the grey pin 6 wires synchronises up to 8 sensors on one machine. Sensors on separate mobile machines cannot be synchronised; keep them at least 2.5 m apart. Valox enclosure, IP65/IP67/IP69K, -40 – +70 °C.
Telemecanique XXW54P3APL01DM6 technical specifications
| General | |
|---|---|
| Sensor design | Ø54 mm, wide beam |
| Detection system | Diffuse |
| Detection | |
| Nominal sensing distance (Sn) | 3 m; set by software with configuration kit |
| Sensing range (Sd) | 0.425–3 m |
| Blind zone | 425 mm |
| Beam angle | 50° |
| Transmission frequency | 48 kHz |
| Repeat accuracy | 0.1 % |
| Minimum size of detected object | Cylinder Ø12 mm at 3 m |
| Electrical characteristics | |
| Rated supply voltage | 12–24 V DC with reverse polarity protection |
| Supply voltage limits | 9–32 V DC |
| Current consumption | 30 mA |
| Wiring technique | 5-wire |
| Outputs and indicators | |
| Output | 4–20 mA analog + PNP (1 NO or 1 NC, programmable) |
| Load impedance | ≤250 Ω at 12 V DC, ≤850 Ω at 24 V DC; overload and short-circuit protection |
| Maximum switching current | 100 mA (PNP) with overload and short-circuit protection |
| Maximum voltage drop | 2 V |
| Switching frequency | ≤1.6 Hz |
| Status LED | Output state: 1 yellow LED; echo state and power on: 1 green/white LED |
| Synchronisation | Yes; up to 8 sensors by connecting all pin 6 (grey) wires; all sensors must be the same model with the same cycle time setting |
| Environmental | |
| Degree of protection | IP65 (IEC 60529), IP67 (IEC 60529), IP69K (DIN 40050) |
| Operating temperature | -40 – +70 °C |
| Certifications and marking | CE, cULus, E2 |
| Mechanical and connection | |
| Enclosure material | Valox |
| Front face material | ULTEM |
| Electrical connection | 0.15 m cable + Deutsch DTM04-6P male connector (6-pin; pin 5 not connected, sealing plug) |
| Dimensions (height × width × depth) | 54 × 79 × 32.5 mm |
| Net weight | 0.115 kg |
| Tightening torque | ≤3 Nm |
| Flush mounting | E max 10 mm, hole Ø min 33 mm; supplied with 2 stainless steel inserts and 2 silicone washers, M4 screws not provided |
Key features
- 50° wide beam from a Ø54 mm body, 0.425–3 m sensing range
- 4–20 mA analog output + programmable PNP output (1 NO or 1 NC)
- Configuration by configurator software (XXZKITDM6 jumper)
- Synchronisation of up to 8 sensors via pin 6
- IP65, IP67 and IP69K protection; -40 – +70 °C operating temperature
- 0.15 m cable + Deutsch DTM04-6P connector; E2 and cULus
XXW54P3APL01DM6 ordering codes
| Part number | Description |
|---|---|
| XXW54P3APL01DM6 | 4–20 mA + PNP, 0.15 m cable + Deutsch DTM04-6P male connector |
| XXW54P3APL01M12 | 4–20 mA + PNP, 0.15 m cable + M12 5-pin male connector |
| XXW54P3APL05 | 4–20 mA + PNP, 0.5 m cable |
| XXW54P3HPL01DM6 | 0.5–4.5 V + PNP, 0.15 m cable + Deutsch DTM04-6P male connector |
| XXW54P3HPL01M12 | 0.5–4.5 V + PNP, 0.15 m cable + M12 5-pin male connector |
| XXW54P3HPL05 | 0.5–4.5 V + PNP, 0.5 m cable |
| XXW54P3JL01DM6 | CAN SAE J1939 communication, 0.15 m cable + Deutsch DTM04-6P male connector |
| XXW54P3JL05 | CAN SAE J1939 communication, 0.5 m cable |
XXW54P3APL01DM6 accessories
Accessories listed by the manufacturer for this product (ordered separately):
| Part number | Description |
|---|---|
| XXZKITDM6 | Configuration jumper, M12 male 4-pin to Deutsch female 6-pin connector |
Other Telemecanique Diffuse Ultrasonic Sensors
- TELEMECANIQUE XXS18P1AM12 — Ultrasonic sensor, M18, diffuse, 4–20 mA analog output
- TELEMECANIQUE XXS18P1VM12 — Ultrasonic sensor, M18, diffuse, 0–10 V analog output
- TELEMECANIQUE XXA18P1AM12 — Ultrasonic sensor, M18, 90° angled head, diffuse, 4–20 mA analog output
- TELEMECANIQUE XXA30P2AM12 — Ultrasonic sensor, M30, 90° angled head, diffuse, 4–20 mA analog output
- TELEMECANIQUE XXA30P2VM12 — Ultrasonic sensor, M30, 90° angled head, diffuse, 0–10 V analog output
- TELEMECANIQUE XX518A3PAM12 — Ultrasonic sensor, M18, diffuse, PNP NO discrete output
- TELEMECANIQUE XX518A3PBM12 — Ultrasonic sensor, Ø18 mm, diffuse, PNP NC discrete output
- TELEMECANIQUE XX630A1NCM12 — Ultrasonic sensor, M30, diffuse, NPN NO + NC discrete output
- TELEMECANIQUE XX7V1A1PAM12 — Ultrasonic sensor, flat form 18 × 33 × 60 mm + M18, diffuse, PNP NO discrete output
- TELEMECANIQUE XXW54P3HPL01DM6 — Ultrasonic sensor, Ø54 mm wide beam, diffuse, 0.5–4.5 V analog + PNP discrete output
Models from other brands: Diffuse Ultrasonic Sensors
Is this ultrasonic sensor right for your application?
Share the object to be detected or the level to be measured (liquid, granules, transparent or coloured surface), the required sensing range, the mounting conditions (adjacent sensors, inclined surface), ambient conditions (dust, vapour, temperature) and your PLC input (analogue 4–20 mA / 0–10 V, PNP/NPN); let’s select the right ultrasonic sensor together.
All product specifications are subject to change without notice. Source: Telemecanique XXW54P3APL01DM6 product data sheet (XXW54P3APL01DM6_EN.pdf, 30 July 2024) https://downloads.telemecaniquesensors.com/dam/datasheets/en/XXW54P3APL01DM6_EN.pdf; reference page https://www.telemecaniquesensors.com/global/en/product/reference/XXW54P3APL01DM6; ordering and accessory codes verified on their reference pages (accessed 28 September 2026).