OMRON G9SA — Safety Relays

Omron G9SA: expandable safety relay unit; 3 or 5 safety contacts, OFF-delay up to 30 s, two-hand controller, 24 V AC/DC or 100–240 V AC.

Omron G9SA — Expandable safety relay unit (45 mm, PL e / Category 4)

Status: In production

Brand: Omron

Product: Expandable safety relay unit (45 mm, PL e / Category 4)

Safety level: PL e / Category 4 (EN ISO 13849-1), except some models

Master units: 3PST-NO, 5PST-NO, 3PST-NO + DPST-NO OFF-delayed, two-hand controller

Supply voltage: 24 V AC/DC or 100 to 240 V AC

Contact rating: 250 V AC 5 A, 30 V DC 5 A (resistive)

Width: Master unit 45 mm, expansion unit 17.5 mm

Request a quote for price and stock

The Omron G9SA family consists of compact and expandable safety relay units. There are four 45 mm wide master units: the 3-pole G9SA-301, the 5-pole G9SA-501, the G9SA-321-T with 3 instantaneous and 2 OFF-delayed poles, and the G9SA-TH301 two-hand controller. The 17.5 mm wide G9SA-EX301 and OFF-delayed G9SA-EX031-T expansion units connect via the front connector, so safety contacts can be multiplied easily. Master units accept 1-channel or 2-channel input; the two-hand controller uses 2 channels. The units conform to EN ISO 13849-1 PL e / Category 4 (except some models).

Contacts are rated 250 V AC 5 A and 30 V DC 5 A resistive, with a rated carry current of 5 A. The operating time is 30 ms max. and the response time 10 ms max. On OFF-delay models the delay is set in 15 steps, with a maximum of 7.5 s on T075, 15 s on T15 and 30 s on T30. Mechanical durability is 5,000,000 operations min. and electrical durability 100,000 operations min. The supply is 24 V AC/DC or 100 to 240 V AC and must be specified when ordering. DIN track or screw mounting is possible; the operating temperature is −25 to 55 °C.

Omron G9SA technical specifications

General
Input channels1 or 2 channels (two-hand controller: 2 channels)
Reset modeManual or automatic (selected with terminals A – B)
MountingDIN track or screw mounting
Safety ratings
Performance level / categoryPL e / Category 4 (EN ISO 13849-1), except some models
OFF-delay settings15 steps; T075: 0.5 to 7.5 s, T15: 1 to 15 s, T30: 2 to 30 s
Electrical characteristics
Power supply voltage24 V AC/DC (24 V AC 50/60 Hz or 24 V DC); 100 to 240 V AC 50/60 Hz
Operating voltage range85% to 110% of rated supply voltage
Input current40 mA max. (301 / 321-T / TH301); 60 mA max. (501)
Rated load (resistive)250 V AC 5 A; 30 V DC 5 A
Rated carry current5 A
Contact resistance100 mΩ
Isolation voltage (Ui) / impulse withstand voltage (Uimp)250 V AC / 4 kV
Outputs and indicators
Operating time30 ms max. (not including bounce time)
Response time10 ms max.
Mechanical durability5,000,000 operations min. (approx. 7,200 operations/h)
Electrical durability100,000 operations min. (approx. 1,800 operations/h)
Minimum permissible load (reference)5 V DC, 1 mA
Environmental
Ambient operating temperature−25 to 55 °C (no icing or condensation)
Storage temperature−25 to 85 °C
Ambient operating humidity35% to 85%
Vibration / shock resistance10 to 55 to 10 Hz, 0.375 mm single amplitude / destruction 300 m/s², malfunction 100 m/s²
Mechanical and connection
Terminal tightening torque0.6 N·m

Omron G9SA models

CodeMain contactsOFF-delay contactsAuxiliary contactMax. OFF-delayWidthPower consumption (24 V AC/DC)Weight
G9SA-3013PST-NO—SPST-NC—45 mm5.7 VA / 1.7 W max.Approx. 210 g
G9SA-5015PST-NO—SPST-NC—45 mm7.4 VA / 2.6 W max.Approx. 270 g
G9SA-321-T0753PST-NODPST-NOSPST-NC7.5 s45 mm8.6 VA / 3.3 W max.Approx. 270 g
G9SA-321-T153PST-NODPST-NOSPST-NC15 s45 mm8.6 VA / 3.3 W max.Approx. 270 g
G9SA-321-T303PST-NODPST-NOSPST-NC30 s45 mm8.6 VA / 3.3 W max.Approx. 270 g
G9SA-TH3013PST-NO—SPST-NC—45 mm5.7 VA / 1.7 W max.Approx. 210 g
G9SA-EX3013PST-NO—SPST-NC—17.5 mmAdds 2 VA / 2 W max. to master unitApprox. 130 g
G9SA-EX031-T075—3PST-NOSPST-NC7.5 s17.5 mmAdds 2 VA / 2 W max. to master unitApprox. 130 g
G9SA-EX031-T15—3PST-NOSPST-NC15 s17.5 mmAdds 2 VA / 2 W max. to master unitApprox. 130 g
G9SA-EX031-T30—3PST-NOSPST-NC30 s17.5 mmAdds 2 VA / 2 W max. to master unitApprox. 130 g

Key features

  • 45 mm master units, 17.5 mm expansion units
  • Safe OFF-delay timer (15 steps)
  • Simple expansion connection on the front
  • Two-hand controller option
  • 24 V AC/DC and 100 to 240 V AC supply options
  • DIN track and screw mounting

G9SA ordering codes

Part numberDescription
G9SA-301Emergency-stop unit, 3PST-NO + SPST-NC, 1 or 2 channels, 24 V AC/DC or 100 to 240 V AC (specify when ordering)
G9SA-501Emergency-stop unit, 5PST-NO + SPST-NC, 1 or 2 channels, 24 V AC/DC or 100 to 240 V AC (specify when ordering)
G9SA-321-T075Emergency-stop OFF-delay unit, 3PST-NO + DPST-NO OFF-delayed (7.5 s) + SPST-NC, 24 V AC/DC or 100 to 240 V AC (specify when ordering)
G9SA-321-T15Emergency-stop OFF-delay unit, 3PST-NO + DPST-NO OFF-delayed (15 s) + SPST-NC, 24 V AC/DC or 100 to 240 V AC (specify when ordering)
G9SA-321-T30Emergency-stop OFF-delay unit, 3PST-NO + DPST-NO OFF-delayed (30 s) + SPST-NC, 24 V AC/DC or 100 to 240 V AC (specify when ordering)
G9SA-TH301Two-hand controller, 3PST-NO + SPST-NC, 2 channels, 24 V AC/DC or 100 to 240 V AC (specify when ordering)
G9SA-EX301Expansion unit, 3PST-NO + SPST-NC; connects to G9SA-301 / 501 / 321 / TH301
G9SA-EX031-T075Expansion unit with OFF-delay outputs, 3PST-NO (7.5 s) + SPST-NC
G9SA-EX031-T15Expansion unit with OFF-delay outputs, 3PST-NO (15 s) + SPST-NC
G9SA-EX031-T30Expansion unit with OFF-delay outputs, 3PST-NO (30 s) + SPST-NC

Other Omron Safety Relays

  • OMRON G9SE — Slim safety relay unit (17.5 / 22.5 mm, PL e)
  • OMRON G9SB — Slim safety relay unit (17.5 / 22.5 mm)
  • OMRON G9SR — Compact safety relay unit (modular, PL e / SIL 3)
  • OMRON G9SX — Scalable hardwired safety controller (flexible safety unit, PL e / SIL 3)
  • OMRON G7SA — Relay with forcibly guided contacts (4 / 6 poles, 6 A)

Models from other brands: Safety Relays

Is this safety relay right for your application?

Share the safety inputs to be connected (emergency stop, door switch, light curtain), the number of output contacts, the need for off-delayed outputs, the supply voltage and the required performance level (PL); let’s select the right unit together.

Request a quote Back to Safety Relays

All product specifications are subject to change without notice. Validation of the safety function and the risk assessment remain the responsibility of the machine builder. Source: Omron industrial.omron.eu/en/products/g9sa; G9SA Safety Relay Unit datasheet, CSM_G9SA_DS_E_11_15 (accessed 25 September 2026).