TELEMECANIQUE XCSPL562 — Safety Door Switches
Telemecanique XCSPL562: hinge-type safety switch, straight lever, 1 NC + 1 NO, 5° tripping angle, M16 entry, up to PL e, IP67.

Status: In production
Brand: Telemecanique
Product: Hinge-type safety switch with straight lever, 1 NC + 1 NO
Contacts: 1 NC + 1 NO
Tripping angle: 5°
Type of operator: Straight lever, to right or to left
Performance level (PL): Up to PL e, SIL 3, category 4 (with appropriate monitoring)
Degree of protection: IP67
The Telemecanique XCSPL562 is a hinge-type safety switch from the XCS range. It has a turret head with rotary lever and a stainless steel straight lever operating to the right or to the left. Contacts are 1 NC + 1 NO, slow-break, break before make, with positive opening of the NC contact (minimum torque 0.25 N·m). The tripping angle is 5° and the minimum tripping torque 0.1 N·m. The double-insulated body is glass-fibre reinforced polyamide PA66. With appropriate monitoring and correct wiring it can reach category 4 and PL e to EN/ISO 13849-1 and SIL 3 to IEC 61508.
It has one M16 × 1.5 tapped cable entry for cable diameters of 7–10 mm. Rated operational current is 6 A at 120 V and 3 A at 240 V in AC-15, and 0.55 A at 125 V and 0.27 A at 250 V in DC-13; thermal current is 10 A. Mechanical durability is 1,000,000 cycles and B10d is 5,000,000. Dimensions are 103 × 88 × 30 mm and weight is 0.095 kg. Vibration resistance is 50 gn and shock resistance 50 gn. Operating temperature is -25 to +70 °C, degree of protection IP67; UL, CSA and BG certified.
Telemecanique XCSPL562 technical specifications
| General | |
|---|---|
| Product type | Hinge-type safety switch (guard switch) |
| Product range | XCS (XCSPL) |
| Type of operator | Straight lever, to right or to left |
| Head type | Turret head, rotary lever |
| Safety ratings | |
| Safety category | Up to category 4 with the appropriate monitoring system and correct wiring (ISO 13849-1) |
| Performance level (PL) | Up to PL e with the appropriate monitoring system and correct wiring (ISO 13849-1) |
| Safety integrity level (SIL) | Up to SIL 3 with the appropriate monitoring system and correct wiring (IEC 61508) |
| B10d | 5,000,000 (for a life time of 20 years) |
| Positive opening | Yes (NC contacts) |
| Positive opening minimum torque | 0.25 N·m |
| Electrical characteristics | |
| Contacts | 1 NC + 1 NO |
| Contact operation | Slow-break, break before make |
| Rated operational current | AC-15 A300: 6 A at 120 V, 3 A at 240 V; DC-13 Q300: 0.55 A at 125 V, 0.27 A at 250 V |
| Conventional enclosed thermal current (Ithe) | 10 A |
| Rated insulation voltage (Ui) | 500 V, pollution degree 3 (IEC 60947-1); 300 V (UL 508, CSA C22.2 No 14) |
| Mechanical and connection | |
| Cable entry | 1 entry tapped for M16 × 1.5 |
| Terminal clamping capacity | 1 × 0.5 mm² to 2 × 1.5 mm², with or without cable end |
| Tripping angle | 5° |
| Minimum torque for tripping | 0.1 N·m |
| Mechanical durability | 1,000,000 cycles |
| Housing material | Polyamide PA66, glass-fibre reinforced |
| Lever / spindle material | Stainless steel |
| Dimensions (W × H × D) | 103 × 88 × 30 mm |
| Net weight | 0.095 kg |
| Environmental | |
| Operating temperature | -25 to +70 °C |
| Vibration resistance | 50 gn, f = 10–500 Hz (IEC 60068-2-6) |
| Electrical shock protection class | Class II (IEC 61140) |
| Degree of protection | IP67 (IEC 60529) |
| Certifications | UL, CSA, BG |
Key features
- Hinge type with stainless steel straight lever, to right or to left
- 5° tripping angle, 0.1 N·m tripping torque
- 1 NC + 1 NO slow-break contacts; positive opening of NC contact
- Up to category 4, PL e and SIL 3 with appropriate monitoring
- Double-insulated glass-fibre reinforced PA66 body, IP67
- 50 gn vibration and shock resistance
XCSPL562 ordering codes
| Part number | Description |
|---|---|
| XCSPL562 | Hinge-type safety switch XCSPL, straight lever (to right or left), 1 NC + 1 NO, M16 entry |
Other Telemecanique Safety Door Switches
- TELEMECANIQUE XCSA — Metal safety interlock switch with separate actuator (key-operated)
- TELEMECANIQUE XCSB701 — Metal safety interlock switch with separate actuator (key-operated)
- TELEMECANIQUE XCSC701 — Metal safety interlock switch with separate actuator (key-operated)
- TELEMECANIQUE XCSPA — Plastic safety interlock switch with separate actuator (key-operated)
- TELEMECANIQUE XCSTA591 — Plastic safety interlock switch with separate actuator (key-operated)
- TELEMECANIQUE XCSLF3535312 — Solenoid-locking metal safety interlock switch, 2 NC + 4 NO
- TELEMECANIQUE XCSE7311 — Solenoid-locking metal safety interlock switch, 2 NC + 1 NO
- TELEMECANIQUE XCSLE3535312 — Solenoid-locking plastic safety interlock switch, 2 NC + 4 NO
- TELEMECANIQUE XCSTE5312 — Solenoid-locking plastic safety interlock switch, 1 NC + 1 NO
- TELEMECANIQUE XCSPR562 — Hinge-type safety switch with 80 mm spindle, 1 NC + 1 NO
- TELEMECANIQUE XCSTR562 — Hinge-type safety switch with 80 mm spindle, 1 NC + 2 NO
- TELEMECANIQUE XCSM3902L1 — Miniature metal safety limit switch, roller plunger, 2 NC + 1 NO
- TELEMECANIQUE XCSD3902P20 — Compact metal safety limit switch, roller plunger, 2 NC + 1 NO
- TELEMECANIQUE XCSP3902P20 — Compact plastic safety limit switch, roller plunger, 2 NC + 1 NO
Models from other brands: Safety Door Switches
Is this safety switch right for your application?
Share the guard type (sliding, hinged, cover), the need for guard locking, the contact configuration, the cable entry and the required performance level (PL); let’s select the right switch and actuator together.
All product specifications are subject to change without notice. Validation of the safety function and the risk assessment remain the responsibility of the machine builder. Source: Telemecanique Sensors product data sheets (XCSPL562_EN.pdf, sheet date 30 July 2024; downloads.telemecaniquesensors.com/dam/datasheets/en/) and telemecaniquesensors.com/global/en/product/reference/ reference pages (accessed 25 September 2026).