HIKROBOT MV-CH140-60UM — Area Scan Cameras

14 MP, Stacked BSI, USB3.0, Mono, 27 fps

HIKROBOT MV-CH140-60UM

Status: Available

HIKROBOT part no.: SM000067799

Request a quote and stock check

The MV-CH140-60UM pairs the 14 MP Stacked BSI global-shutter sensor with USB 3.0 bandwidth to reach 27 fps at 4708 × 2824 — more than three times the frame rate of the GigE version of the same sensor. Mono 8/10/10Packed/12/12Packed formats, together with 41.9 dB SNR and 56.9 dB dynamic range, provide the grey-level depth measurement accuracy demands. Exposure is adjustable from 80 μs to 10 s and gain from 0 to 24 dB.

The USB 3.0 interface carries data and powers the camera at the same time (typically 4.0 W at 5 VDC) and is backward compatible with USB 2.0; 9–24 VDC can be applied at the 6-pin P7 connector if preferred. Hardware trigger, software trigger and free run modes are supported, and P7 offers the Line 0 opto-isolated input, Line 1 opto-isolated output and Line 2 bi-directional non-isolated I/O. The 29 × 44 × 59 mm body weighs only 113 g, supports customized ROI with horizontal and vertical reversed image output, and works with USB3 Vision and GenICam-based software.

Specifications

CH Series — High Resolution
ModelMV-CH140-60UM
Performance
Sensor typeCMOS, global shutter
Sensor modelStacked BSI
Pixel size3 μm × 3 μm
Sensor size1″
Resolution4708 × 2824
Max. frame rate27 fps @ 4708 × 2824 Mono 8
Dynamic range56.9 dB
SNR41.9 dB
Gain0 dB to 24 dB
Exposure time80 μs to 10 sec
Exposure modeOff/Once/Continuous exposure mode
Mono/colorMono
Pixel formatMono 8/10/10Packed/12/12Packed
BinningSupports 1 × 1, 2 × 2, 4 × 4
DecimationSupports 1 × 1, 2 × 2, 4 × 4
Reverse imageSupports horizontal and vertical reverse image output
Electrical feature
Data interfaceUSB 3.0, compatible with USB 2.0
Digital I/O6-pin P7 connector provides power and I/O, including opto-isolated input × 1 (Line 0), opto-isolated output × 1 (Line 1), bi-directional non-isolated I/O × 1 (Line 2).
Power supply9 VDC to 24 VDC, supports USB 3.0 power supply
Power consumptionTyp. 4.0 W @ 5 VDC (USB 3.0 provides power supply)
Mechanical
Lens mountC-mount
Dimension29 mm × 44 mm × 59 mm (1.1″ × 1.7″ × 2.3″)
WeightApprox. 113 g (0.2 lb.)
Ingress protectionIP40 (under proper lens installation and wiring)
TemperatureWorking temperature: –10 °C to 50 °C (14 °F to 122 °F)
Storage temperature: –30 °C to 70 °C (–22 °F to 158 °F)
Humidity20% RH to 95% RH (no condensation)
General
Client softwareMVS or third-party software meeting with USB3 Vision Protocol
Operating system32/64-bit Windows 7/10, 64-bit Windows 11, and 32/64-bit Linux
CompatibilityUSB3 Vision, GenICam
CertificationCE, RoHS
HIKROBOT part no.SM000067799
StatusAvailable

Key features

  • Supports auto or manual adjustment of gain, exposure time, Gamma correction, LUT correction, etc.
  • Supports customized ROI, horizontal and vertical reverse image output.
  • Supports hardware trigger, software trigger, free run.
  • Compatible with USB3 Vision Protocol, GenICam Standard, and the third-party software based on the protocol and standard.

Where it is used

At 27 fps the 14 MP resolution becomes usable on continuously moving lines: verifying component placement on electronic boards, counting connector pins and measuring their position, and checking burrs and holes on machined metal parts. Customized ROI lets only the region of interest be read out for even faster inspection cycles, and the USB connection suits compact cells where the camera plugs straight into an industrial PC.

Suitability depends on working distance, field of view, target characteristics and positioning. Selection is assessed on a per-project basis.

Is this camera right for your application?

Let us determine resolution, interface, lens and illumination together, based on your application. FST is HIKROBOT’s distributor in Türkiye; product selection, commissioning and after-sales support all come from one source.

Request a quote Other models in the series

The data herein may vary based on the environment, objects and other various factors, and HIKROBOT shall not assume the consequences arising therefrom.

Source: HIKROBOT product data