TELEMECANIQUE XS9C111A1L2 — Rectangular Inductive Sensors

Telemecanique XS9C111A1L2: Inductive proximity sensor, analogue output, 40×40×15 mm; Sn 15 mm, 0–10 V output, 24 V DC, 2 m cable.

Telemecanique XS9C111A1L2 — Inductive proximity sensor with analogue output, flat form 40×40×15 mm, 0–10 V

Status: In production

Brand: Telemecanique

Product: Inductive proximity sensor with analogue output, flat form 40×40×15 mm, 0–10 V

Nominal sensing distance (Sn): 15 mm

Output: Analogue 0–10 V, 3-wire

Connection: 2 m PVC cable

Supply: 24 V DC

Degree of protection: IP68

Request a quote for price and stock

The Telemecanique XS9C111A1L2 is a flat-form inductive proximity sensor from the XS9 application series measuring 40×40×15 mm. Instead of a switching output it provides a 0–10 V analogue voltage output that depends on the target distance. The nominal sensing distance is 15 mm and the operating zone is 2–15 mm. The PBT enclosure and PBT sensing face are suitable for flush mounting in metal. The rated supply is 24 V DC with limits of 15–36 V DC; no-load current consumption is 0–4 mA.

Repeat accuracy is 3 % of Sr or better; linearity error is ±1 V and maximum output drift is 10 %. The data sheet states a switching frequency of ≤ 1000 Hz. The sensor has no status LED. The 3-wire connection is made through a 2 m PVC cable with 3 × 0.34 mm² conductors. The enclosure is rated IP68 with double insulation (IEC 60529), and the operating temperature range is -25 °C to +70 °C. Minimum mounting distances are 45 mm side by side, 110 mm face to face and 45 mm facing a metal object.

Telemecanique XS9C111A1L2 technical specifications

General
SeriesXS9, application series
Sensor designFlat form 40×40×15 mm (form C)
Enclosure materialPBT (plastic)
Detection faceFrontal, PBT
MountingFlush mountable
Detection
Nominal sensing distance (Sn)15 mm
Operating zone2–15 mm
Repeat accuracy≤ 3 % of Sr
Switching frequency≤ 1000 Hz
Electrical characteristics
Rated supply voltage (Us)24 V DC
Supply voltage limits15–36 V DC
Current consumption0–4 mA (no-load)
Outputs and indicators
Output typeAnalogue, 3-wire, DC
Analogue output range0–10 V
Linearity error±1 V
Maximum output current drift10 %
Status LEDNone
Mechanical and connection
Electrical connectionCable, 2 m
CablePVC, 3 × 0.34 mm²
Minimum mounting distancesSide by side ≥ 45 mm, face to face ≥ 110 mm, facing metal ≥ 45 mm
Environmental
Degree of protectionIP68, double insulation (IEC 60529)
Operating temperature-25 °C to +70 °C
Storage temperature-40 °C to +85 °C
Vibration resistance25 gn, amplitude ±2 mm (f = 10–55 Hz), IEC 60068-2-6
Shock resistance50 gn, 11 ms, IEC 60068-2-27
Certifications and markingCE, UL, CSA, Ecolab

Key features

  • Distance-dependent 0–10 V analogue voltage output
  • Nominal sensing distance Sn 15 mm, operating zone 2–15 mm
  • Linearity error ±1 V, repeat accuracy ≤ 3 % of Sr
  • Flat form 40×40×15 mm, PBT enclosure, flush mountable
  • 24 V DC supply (limits 15–36 V DC), 3-wire
  • IP68 double insulation, 2 m PVC cable

XS9C111A1L2 ordering codes

Part numberDescription
XS9C111A1L2Analogue 0–10 V voltage output, 3-wire, 24 V DC, 2 m cable
XS9C111A2L2Analogue 4–20 mA current output, 2-wire, 24 V DC, 2 m cable

Other Telemecanique Rectangular Inductive Sensors

Models from other brands: Rectangular Inductive Sensors

Is this inductive sensor right for your application?

Share the metal target to be detected (material, size), the required sensing distance, the mounting type (flush / non-flush), ambient conditions (oil, coolant, washdown, temperature) and your PLC input (PNP/NPN, NO/NC); let’s select the right inductive sensor and connection cable together.

Request a quote Back to Rectangular Inductive Sensors

All product specifications are subject to change without notice. Source: Telemecanique, XS9C111A1L2 product data sheet (30 July 2024), https://downloads.telemecaniquesensors.com/dam/datasheets/en/XS9C111A1L2_EN.pdf; product page https://www.telemecaniquesensors.com/global/en/product/reference/XS9C111A1L2 (accessed 28 September 2026).