OMRON A4EG — Emergency Stop & Enabling Switches
Omron A4EG: three-position enabling grip switch; standard, emergency stop and momentary pushbutton models, IP66 / IP65, EN 60947-5-1 direct opening.

Status: In production
Brand: Omron
Product: Three-position enabling grip switch
Enabling switch: 3 positions (OFF – ON – OFF), 2 contacts
Models: With monitor (grip) output; with 2NC emergency stop switch; with 2NO momentary switch
Enabling switch rating: AC-15 0.75 A / 240 V; DC-13 0.55 A / 125 V (EN)
Degree of protection: IP66 (A4EG-C000041), IP65 (others)
Operating temperature: −10 to 55 °C
The Omron A4EG is an enabling grip switch with a distinct feel for three easily discernible positions. Omron’s original double snap action mechanism lets the operator precisely confirm the enable position: released it is OFF, gripped to the middle position it is ON, and gripped further it is OFF again (OFF – ON – OFF). Besides the standard model, there are models with a 2NC emergency stop switch and with a 2NO momentary operation switch. An optional Holding Key provides a versatile method for selecting modes. Safety circuits are easy to configure by combining the A4EG with the G9SX-GS Safety Guard Switching Unit.
The enabling switch section has certified direct opening to EN 60947-5-1 (TÜV SÜD) and is also certified to UL 508, CSA C22.2 No.14 and CCC. EN ratings are AC-15 0.75 A at 240 V and DC-13 0.55 A at 125 V. Electrical durability is 100,000 operations min.; mechanical durability is 100,000 operations min. for OFF – ON – OFF (direct opening) and 1,000,000 operations min. for OFF – ON. Protection is IP66 on the standard model and IP65 on the pushbutton models. The switch is equipped with a conduit connector; the recommended cable diameter is 8.0 to 13 mm. The operating temperature is −10 to 55 °C.
Omron A4EG technical specifications
| General | |
|---|---|
| Enabling switch positions | 3 positions: OFF – ON – OFF |
| Certifications | EN 60947-5-1 (certified direct opening, TÜV SÜD), UL 508, CSA C22.2 No.14, GB/T 14048.5; complies with GS-ET-22 |
| Safety ratings | |
| Conditional short-circuit current | 100 A (EN 60947-5-1); 10 A gI / gG fuse |
| Protection against electric shock | Class II (double insulation) |
| Electrical characteristics | |
| Enabling switch: rated insulation voltage / ON current | 250 V / 2.5 A |
| Enabling switch: rated load | 24 V DC 0.3 A (inductive); 125 V AC 1 A (resistive) |
| Enabling switch: EN rating | AC-15 0.75 A / 240 V; DC-13 0.55 A / 125 V |
| Emergency stop switch (A4EG-BE2R041) | 125 V AC 5 A, 250 V AC 3 A, 30 V DC 3 A (resistive); EN: AC-12 3 A / 250 V, DC-12 3 A / 30 V |
| Pushbutton (A4EG-BM2B041) | EN: AC-12 0.1 A / 125 V, DC-12 0.1 A / 30 V |
| Minimum applicable load | Enabling switch 24 V DC 4 mA; pushbuttons 5 V DC 1 mA |
| Insulation resistance | 100 MΩ min. (at 500 V DC) |
| Environmental | |
| Ambient operating temperature | −10 to 55 °C (no icing or condensation) |
| Ambient storage temperature | −25 to 65 °C |
| Ambient operating humidity | 35% to 85% |
| Degree of protection | IP66 (A4EG-C000041), IP65 (A4EG-BE2R041, A4EG-BM2B041) |
| Vibration / shock (malfunction) | 10 to 55 Hz, 1.5 mm double amplitude / 150 m/s² max. |
| Pollution degree | 3 (EN 60947-5-1) |
| Mechanical and connection | |
| Enabling switch durability | Electrical 100,000 min.; mechanical OFF – ON – OFF 100,000 min., OFF – ON 1,000,000 operations min. |
| Cable entry | Conduit connector; recommended cable diameter 8.0 to 13 mm, AWG20 to 18 |
| Cable pull strength | 30 N, 1 min |
Omron A4EG models
| Code | Enabling switch | Monitor switch | Pushbutton switch | Protection |
|---|---|---|---|---|
| A4EG-C000041 | 2 contacts | 1NC (grip output) | None | IP66 |
| A4EG-BE2R041 | 2 contacts | None | Emergency stop switch (2NC) | IP65 |
| A4EG-BM2B041 | 2 contacts | None | Momentary operation switch (2NO) | IP65 |
Key features
- Three clearly felt positions with the double snap action mechanism
- Standard, emergency stop and momentary pushbutton models
- Mode selection with the optional Holding Key
- Cable entry with conduit connector
- Easy safety circuits with the G9SX-GS Safety Guard Switching Unit
A4EG ordering codes
| Part number | Description |
|---|---|
| A4EG-C000041 | Enabling grip switch, enabling switch 2 contacts + 1NC monitor (grip) output |
| A4EG-BE2R041 | Enabling grip switch, enabling switch 2 contacts + emergency stop switch (2NC) |
| A4EG-BM2B041 | Enabling grip switch, enabling switch 2 contacts + momentary operation switch (2NO) |
A4EG accessories
Accessories listed by the manufacturer for this product (ordered separately):
| Part number | Description |
|---|---|
| A4EG-OP1 | Rubber cover (replacement part) |
| A4EG-OP2 | Mounting bracket (for securing the A4EG) |
| A4EG-OP3 | Holding key |
| G9SX-GS226-T15-RT | Safety guard switching unit, 2 instantaneous + 2 OFF-delayed safety outputs (15 s max.), screw terminals |
| G9SX-GS226-T15-RC | Safety guard switching unit, 2 instantaneous + 2 OFF-delayed safety outputs (15 s max.), spring-cage terminals |
Other Omron Emergency Stop & Enabling Switches
- OMRON A22E — Emergency stop pushbutton switch (40 mm dia., push-lock / turn-reset, screw terminals)
- OMRON A165E — Emergency stop switch (16 mm dia. panel cutout, 30 / 40 mm dia. pushbutton)
Models from other brands: Emergency Stop & Enabling Switches
Is this switch right for your application?
Share the machine to be stopped, the place of use (panel, along the line, handheld pendant), the contact configuration and the required performance level (PL); let’s select the right emergency stop or enabling switch together.
All product specifications are subject to change without notice. Validation of the safety function and the risk assessment remain the responsibility of the machine builder. Source: Omron industrial.omron.eu/en/products/a4eg; A4EG Enabling Grip Switch datasheet, CSM_A4EG_DS_E_9_1 (accessed 25 September 2026).