HIKROBOT MV-CL042-91CM-V2 — Line Scan Cameras

4096×2, Camera Link, Mono, 195 kHz

The MV-CL042-91CM-V2 is a 4096×2 monochrome line-scan camera from HIKROBOT’s CL Series, built around a Camera Link interface. It applies multiple ISP tools — manually adjustable Gamma correction, flat correction, LUT, and black level — and supports multiple exposure and acquisition modes with a maximum line rate of 195 kHz.

Specifications

ModelMV-CL042-91CM-V2
Sensor typeCMOS
Pixel size7 μm
Resolution4096 × 2
Image modeSupports 1-line and 2-TDI
Max. line rate40.5 kHz (Base), 81 kHz (Medium), 162 kHz (Full), 195 kHz (80-bit)
Configuration modeBase, Medium, Full, 80-bit
Tap geometry1 × 2, 1 × 4, 1 × 8, 1 × 10
Tap number2 Taps, 4 Taps, 8 Taps, 10 Taps
Pixel clock40 MHz, 66 MHz, 80 MHz, 85 MHz
Dynamic range65.6 dB
SNR40 dB
GainSupports 1.0 ×, 1.4 ×, 1.6 ×, 2.4 ×, 3.2 ×
Exposure time3 μs to 10 ms
Exposure modeOff/ Once/ Continuous exposure mode; supports fixed time exposure, trigger-width exposure
MonoMono
Pixel formatMono 8/10/12
BinningSupports 1 × 1, 1 × 2, 1 × 4, 2 × 1, 2 × 2, 2 × 4, 4 × 1, 4 × 2, 4 × 4
Reverse imageSupports horizontal reverse image output
Trigger modeExternal trigger, internal trigger
External trigger modeLine trigger, frame trigger, line + frame trigger
Data interfaceCamera Link (SDR connector); USB interface for updating firmware
Digital I/O12-pin P10 connector provides power and I/O: configurable input/output × 4 (Line 0/1/3/4) and support single-ended/differential. Camera Link provides I/O (CC1/CC2/CC3/CC4).
Power supply12 VDC to 24 VDC
Power consumptionTyp. 8 W @ 12 VDC
Lens mountM42*1.0, flange back length 12 mm, applicable to F-mount, C-mount and lens of other types via lens adapter
Dimension62 mm × 62 mm × 36.9 mm (2.4″ × 2.4″ × 1.5″)
WeightApprox. 238 g (0.5 lb.)
Ingress protectionIP40 (under proper lens installation and wiring)
TemperatureWorking temperature: –20 °C to 45 °C (–4 °F to 113 °F)
Storage temperature : –30 °C to 80 °C (–22 °F to 176 °F)
Humidity5% RH to 95% RH (no condensation)
Client softwareMVS and frame grabber software meeting with Camera Link Protocol
Operating system32/64-bit Windows 7/10, 64-bit Windows 11
CompatibilityCamera Link V2.1, GenICam
CertificationCE, RoHS, KC

Key features

  • Adopts multiple ISP technologies and supports manual adjustment for Gamma correction, flat correction, LUT, and black level.
  • Supports multiple exposure and image acquisition methods with a max. line rate of 195 kHz.
  • Supports bi-directional I/O wiring for flexible input/output settings.
  • Compact design and flexible installation.
  • Compatible with Camera Link Protocol and GenICam Standard.

Where it is used

With its Camera Link interface and high line rate, this camera suits high-speed continuous-web inspection lines — printing, film, and metal strip — where short cable runs to a frame grabber are practical. Its mono sensor is well suited to surface-defect, scratch, and texture-contrast inspection where color information is not required.

Suitability depends on working distance, field of view, target characteristics and positioning. Selection is assessed on a per-project basis.

Is this camera right for your application?

Let us determine resolution, interface, lens and illumination together, based on your application. FST Teknoloji provides technical services in optics selection, system integration, commissioning and application engineering.

Request a technical consultation Other models in the series

Values are compiled from manufacturer documentation and may vary with the environment, the object and product revisions.

← Line Scan Camera Models