HIKROBOT MV-CA017-10GM — Area Scan Cameras
1.7 MP, Sony IMX432, GigE, Mono, 68.5 fps

The MV-CA017-10GM stands out within the CA series for its sensor pairing: Sony’s 1.1″ IMX432 sensor with a large 9 μm pixel delivers 68.5 fps at 1608 × 1104. That large pixel combined with a 72.44 dB dynamic range points toward low-light sensitivity, and the camera offers two exposure modes – 1-5 μs UltraShort and 6 μs-10 sec standard. The model carries ‘Delisting Preparation’ status at HIKROBOT.
The GigE interface runs up to 100 meters without a relay and stays compatible with Fast Ethernet; a 6-pin Hirose connector carries 12 VDC or PoE power alongside the opto-isolated I/O set. High-sensitivity and high-full-well modes let the sensor’s behavior be tuned to different lighting conditions, and a 2D noise-reduction function is also included. GigE Vision V2.0 / GenICam compliance supports integration with third-party software.
Specifications
| CA Series — Area Scan | |
|---|---|
| Model | MV-CA017-10GM |
| Performance | |
| Sensor type | CMOS, global shutter |
| Sensor model | Sony® IMX432 |
| Pixel size | 9 μm × 9 μm |
| Sensor size | 1.1″ |
| Resolution | 1608 × 1104 |
| Max. frame rate | 68.5 fps @ 1608 × 1104 |
| Dynamic range | 72.44 dB |
| SNR | 40 dB |
| Gain | 0 dB to 24 dB |
| Exposure time | UltraShort exposure mode: 1 μs to 5 μs Standard exposure mode: 6 μs to 10 sec |
| Exposure mode | Off/Once/Continuous exposure mode |
| Mono | Mono |
| Pixel format | Mono 8/10/10p/12/12p |
| Binning | Supports 1 × 1, 1 × 2, 1 × 4, 2 × 1, 2 × 2, 2 × 4, 4 × 1, 4 × 2, 4 × 4 |
| Decimation | Supports 1 × 1, 1 × 2, 1 × 4, 2 × 1, 2 × 2, 2 × 4, 4 × 1, 4 × 2, 4 × 4 |
| Reverse image | Supports horizontal and vertical reverse image output |
| Electrical feature | |
| Data interface | Gigabit Ethernet, compatible with Fast Ethernet |
| Digital I/O | 6-pin Hirose connector provides power and I/O, including opto-isolated input × 1 (Line 0), opto-isolated output × 1 (Line 1), bi-directional non-isolated I/O × 1 (Line 2). |
| Power supply | 12 VDC, supports PoE |
| Power consumption | Typ. 4.2 W @ 12 VDC |
| Mechanical | |
| Lens mount | C-mount |
| Dimension | 29 mm × 44 mm × 59 mm (1.1″ × 1.7″ × 2.3″) |
| Weight | Approx. 100 g (0.22 lb.) |
| Ingress protection | IP30 (under proper lens installation and wiring) |
| Temperature | Working temperature: 0 °C to 50 °C (32 °F to 122 °F) Storage temperature: –30 °C to 70 °C (–22 °F to 158 °F) |
| Humidity | 20% RH to 80% RH (no condensation) |
| General | |
| Client software | MVS or third-party software meeting with GigE Vision Protocol |
| Operating system | 32/64-bit Windows 7/10, 32/64-bit Linux |
| Compatibility | GigE Vision V2.0, GenICam |
| Certification | CE, RoHS, KC |
| HIKROBOT part no. | SM000032556 |
| Status | Being discontinued |
Key features
- Supports auto or manual adjustment for gain, exposure time, LUT, Gamma correction, white balance, etc.
- Supports 2D noise reduction function.
- Supports high sensitivity mode and high full well mode.
- Adopts GigE interface and max. transmission distance of 100 meters without relay.
- Compatible with GigE Vision V2.0 Protocol, GenICam Standard, and third-party software based on the protocol and standard.
Where it is used
The large pixel size and wide dynamic range help on lines working with low light or reflective surfaces – such as metal-part inspection or low-contrast surface checks. The 1.7 MP resolution and 1.1″ sensor’s wider field of view make it easier to cover larger parts in a single frame. The high-sensitivity mode can also reduce the need for supplementary lighting in dim environments.
Suitability depends on working distance, field of view, target characteristics and positioning. Selection is assessed on a per-project basis.
Is this camera right for your application?
Let us determine resolution, interface, lens and illumination together, based on your application. FST is HIKROBOT’s distributor in Türkiye; product selection, commissioning and after-sales support all come from one source.
The data herein may vary based on the environment, objects and other various factors, and HIKROBOT shall not assume the consequences arising therefrom.
Source: HIKROBOT product data