PANASONIC SF-C21 — Safety Relays

Panasonic SF-C21: safety control unit, Category 4, PL e, SILCL 3, 8 safety inputs, 2×2 PNP outputs, 8 preset logics, 10 ms.

Panasonic SF-C21 — Safety control unit (8 preset logics, PL e)

Status: In production

Brand: Panasonic

Product: Safety control unit (8 preset logics, PL e)

Safety level: Category 4, PL e, SIL 3, SILCL 3

Safety inputs: 2 × 4 (IN1–IN8)

Control outputs: PNP, 2 outputs × 2, max. 300 mA per output

Response time (ON→OFF): 10 ms or less

Size: height 97 mm × width 45 mm

Request a quote for price and stock

The Panasonic SF-C21 is a safety control unit that requires no programming skills; according to the manufacturer one unit does the work of four safety relay units. It meets Category 4, PL e to ISO 13849-1:2015, SIL 3 to IEC 61508 and SILCL 3 to IEC 62061. It has 2 × 4 safety inputs, 2 reset/EDM inputs, 2 × 2 PNP control outputs and 4 auxiliary outputs. A rotary switch selects one of eight preset logics certified up to Category 4, PL e; a user-customised logic is stored as logic No. 0. At 97 mm × 45 mm it fits into narrow panels.

Preset logics: overall stop, parallel muting, sequential muting, partial stop 1 and 2, two-hand control, OR control and operation mode selection. The OFF delay of control output 2 is set in ten steps from 0 to 60 s with a rotary switch. The free Configurator SF-C software customises logic, assigns auxiliary outputs and sets ON/OFF delay and muting time; customised logics are also safety-certified. Via RS-485 (MODBUS RTU), status and error history of up to 8 units can be read by a general-purpose PLC; this information cannot be used for safety control. Input filter time setting and an exit-only muting function have been added.

Panasonic SF-C21 technical specifications

General
Safety standardsIEC 61508-1 to 3 (SIL 3), ISO 13849-1:2015 (Category 4, PL e), IEC 62061 (SILCL 3), IEC 61131-2, IEC 61010-2-201, UL 61010-1, UL 1998
EMC standardsIEC 61000-6-2, IEC 61326-3-1, EN 55011
CertificationsCE, UKCA, TÜV SÜD, TÜV SÜD (USA, Canada), Korea Radio Waves Act registration
Safety ratings
PFHd / MTTFd9.73×10⁻¹⁰ / 100 years or more
Logic selectionNo.0 custom, No.1–8 preset logics (rotary switch)
Interlock / lockout release / EDMincorporated
Electrical characteristics
Supply voltageinternal and external supply: 24 V DC +10 / -15 %, ripple P-P 10 % or less
Current consumptioninternal supply 200 mA, external supply 100 mA or less
Safety input (IN1–IN8)2 × 4 inputs; ON level 18 V / 3.5 mA, OFF level 5 V / 1.0 mA; approx. 5 mA, 4.7 kΩ
Startup time2 s or less after power on
Outputs and indicators
Control output (OUT1–OUT4)PNP open collector, 2 outputs × 2, max. 300 mA per output; short-circuit protected
Response timeOFF: 10 ms or less, ON: 100 ms or less
ON / OFF delayOFF 0.0–60.0 s (0.1 s steps), ON 1–5,940 s (via software)
Auxiliary output (AUX1–AUX4)PNP open collector, 1 output × 4, max. 60 mA
Muting indicator outputsemiconductor photo MOS relay × 1, max. 60 mA
CommunicationRS-485, MODBUS RTU, max. 100 m, 8 units (slaves)
Environmental
Degree of protectionIP20 (IEC); must be installed in a control panel rated IP54 or higher
Operating temperature-10 to +55 °C (no condensation or icing)
Storage temperature-25 to +60 °C
Ambient humidity30–85 % RH
Shock resistance147 m/s² (15 G), 11 ms, X, Y and Z three times each
Mechanical and connection
Connectiondetachable spring-cage terminal blocks; USB Mini-B
Maximum cable length100 m or less
Enclosure materialpolycarbonate / ABS polymer alloy; enclosure polycarbonate
Weightnet approx. 190 g, gross approx. 320 g

Key features

  • One unit replaces four safety relay units; 97 mm × 45 mm
  • 8 preset logics certified up to Category 4, PL e, selected by rotary switch
  • Custom logic with Configurator SF-C software without programming; custom logics are also safety-certified
  • Long-life semiconductor (PNP) control and auxiliary outputs
  • Status monitoring from a general-purpose PLC via RS-485 (MODBUS RTU)
  • Input filter time setting and exit-only muting function

SF-C21 ordering codes

Part numberDescription
SF-C21safety control unit: safety input 2×4, reset/EDM input 2, control output 2×2, auxiliary output 4

Other Panasonic Safety Relays

Models from other brands: Safety Relays

Is this safety relay right for your application?

Share the safety inputs to be connected (emergency stop, door switch, light curtain), the number of output contacts, the need for off-delayed outputs, the supply voltage and the required performance level (PL); let’s select the right unit together.

Request a quote Back to Safety Relays

All product specifications are subject to change without notice. Validation of the safety function and the risk assessment remain the responsibility of the machine builder. Source: Panasonic Industry, https://industry.panasonic.com/global/en/products/fasys/sensor/safety/sf-c21, https://industry.panasonic.com/global/en/products/fasys/sensor/safety/number/sf-c21 (accessed 25 September 2026).