PANASONIC SF-C10 — Safety Relays

Panasonic SF-C10: light curtain control unit, Category 4, PL e, 3 NO positively driven safety contacts, 10 ms response, SF-C11 / SF-C13.

Panasonic SF-C10 — Control unit for safety light curtains (relay output)

Status: In production

Brand: Panasonic

Product: Control unit for safety light curtains (relay output)

Safety level: Category 4, PL e (ISO 13849-1:2015), Type 4 (IEC 61496-1)

Safety output: NO contact × 3, positively driven

Response time (ON→OFF): 10 ms or less

Supply: 24 V DC ±10 %, 100 mA or less

Models: SF-C11 (connector connection), SF-C13 (slim type, 22.5 mm)

Request a quote for price and stock

The Panasonic SF-C10 series consists of exclusive control units for safety light curtains and shortens setup time for safety circuits. The SF-C11 plugs into the SF4D light curtain with an 8-core connector cable; the muting function cannot be used. The SF-C13 is a slim type only 22.5 mm thick that connects to Panasonic light curtains by discrete wire cable, and the muting function can be used. Both models are compatible up to Category 4 and support presses used in Japan together with SF4D-□-01. One model is set to match PNP or NPN light curtain output.

The safety output is three NO contacts (13-14, 23-24, 33-34); contacts are AgSnO, self-cleaning and positively driven. The SF-C11 is rated 30 V DC / 6 A and 230 V AC / 6 A, the SF-C13 30 V DC / 4 A and 230 V AC / 4 A. Response time is 10 ms or less; mechanical life is min. 10,000,000 and electrical life min. 100,000 operations. External relay monitoring and trailing edge functions are built in. The electronic fuse trips at 0.5 A and resets after power down. The enclosure is ABS, protection IP40 and terminals IP20.

Panasonic SF-C10 technical specifications

General
Applicable standardsEN / IEC 61496-1 (Type 4), EN ISO / ISO 13849-1:2015 (Category 4, PL e), EN 55011, JIS B 9704-1, JIS B 9705-1, ANSI/UL 61496-1, UL 1998 (Class 2)
CertificationsCE, UKCA, UL/c-UL Listing, TÜV SÜD
Connectable light curtainsSF-C11: SF4D series; SF-C13: safety light curtains by Panasonic Industry
Safety ratings
B10dminimum load 20,000,000, maximum load 400,000
Mission time20 years
External relay monitor / trailing edge functionincorporated
Electrical characteristics
Supply voltage / current consumption24 V DC ±10 %, ripple P-P 10 % or less / 100 mA or less (without light curtain)
Fusebuilt-in electronic fuse, trips at 0.5 A or more, resets after power down
Polarity selectionSF-C11 by sliding switch, SF-C13 by cable connection; minus ground for PNP, plus ground for NPN light curtains
Outputs and indicators
Safety outputNO contact × 3 (13-14, 23-24, 33-34), AC-15 / DC-13 (IEC 60947-5-1)
Rated voltage / currentSF-C11: 30 V DC / 6 A, 230 V AC / 6 A; SF-C13: 30 V DC / 4 A, 230 V AC / 4 A; min. load 10 mA (24 V DC)
Contact materialAgSnO, self-cleaning, positively driven
Response timedrop-out delay 10 ms or less; pick-up delay 80 ms (auto) / 90 ms (manual) or less
Mechanical / electrical lifemin. 10,000,000 (180 per minute) / min. 100,000 operations (20 per minute, 230 V AC 3 A)
Auxiliary outputsafety relay NC contact × 1 (41-42), 24 V DC / 2 A; semiconductor AUX PNP/NPN, max. 60 mA
Environmental
Degree of protectionenclosure IP40, terminal IP20
Operating temperature-10 to +55 °C (no condensation or icing)
Storage temperature-25 to +70 °C
Ambient humidity30–85 % RH (storage 30–95 % RH)
Vibration resistance10–55 Hz, 0.35 mm amplitude, X, Y and Z 20 times each
Mechanical and connection
Connection terminalSF-C11 detachable spring-cage terminal; SF-C13 spring-cage terminal
Enclosure materialABS
WeightSF-C11 approx. 320 g, SF-C13 approx. 200 g

Panasonic SF-C10 models

ModelTypeLight curtain connectionMutingContact ratingContact protection fuseWeight
SF-C11connector connection typeSF4D, 8-core connector cable (SFD-CB□, SFB-CCJ□)not available6 A (30 V DC / 230 V AC)6 Aapprox. 320 g
SF-C13slim type (22.5 mm)discrete wire cable (SFD-CCB□, SFD-CC□ for SF4D)available4 A (30 V DC / 230 V AC)4 Aapprox. 200 g

Key features

  • SF-C11: plug-in connector connection shortens setup and replacement time
  • SF-C11: removable spring-type terminal blocks with no torque control
  • SF-C13: slim type only 22.5 mm thick, fits narrow panel spaces
  • PNP/NPN polarity selection on all models
  • 3 NO safety outputs with positively driven, self-cleaning AgSnO contacts
  • Built-in electronic fuse that needs no replacement

SF-C10 ordering codes

Part numberDescription
SF-C11connector connection type control unit for SF4D, Category 4 (supports presses in Japan, not shearing machines)
SF-C13slim type control unit, discrete wire connection, muting available, Category 4

SF-C10 accessories

Accessories listed by the manufacturer for this product (ordered separately):

Part numberDescription
SFD-CB05SF4D bottom cap cable with connector, 8-core, 0.5 m (for SF-C11 connection)
SFB-CCJ3Eextension cable with connectors on both ends, emitter, 3 m (for SF-C11 connection)
SFB-CCJ3Dextension cable with connectors on both ends, receiver, 3 m (for SF-C11 connection)
SFD-CCB3SF4D bottom cap cable, discrete wire, 8-core, 3 m (for SF-C13 connection)
SFD-CC3SF4D extension cable with connector on one end, 3 m (for SF-C13 connection)

Other Panasonic Safety Relays

Models from other brands: Safety Relays

Is this safety relay right for your application?

Share the safety inputs to be connected (emergency stop, door switch, light curtain), the number of output contacts, the need for off-delayed outputs, the supply voltage and the required performance level (PL); let’s select the right unit together.

Request a quote Back to Safety Relays

All product specifications are subject to change without notice. Validation of the safety function and the risk assessment remain the responsibility of the machine builder. Source: Panasonic Industry, https://industry.panasonic.com/global/en/products/fasys/sensor/safety/sf-c10, https://industry.panasonic.com/global/en/products/fasys/sensor/safety/number/sf-c11, https://industry.panasonic.com/global/en/products/fasys/sensor/safety/number/sf-c13 (accessed 25 September 2026).