TELEMECANIQUE XY2CH — Emergency Stop & Enabling Switches
Telemecanique XY2CH: latching emergency stop rope pull switch, trigger cable up to 30 m, 1 NC + 1 NO or 2 NC, booted reset button, IP65.

Status: In production
Brand: Telemecanique
Product: Emergency stop rope pull switch (trigger cable up to 30 m)
Trigger cable maximum length: 30 m
Contacts: 1 NC + 1 NO (XY2CH13250) or 2 NC (XY2CH13270)
Reset: Booted push-button
Performance level (PL): Up to PL e, SIL 3, category 4 (with appropriate monitoring)
Degree of protection: IP65
The Telemecanique XY2CH is a latching emergency stop rope pull switch from the XY2C range. It works with a single trigger cable up to 30 m long, which can be anchored on the right-hand or left-hand side. Distance between cable supports is 5 m. When tripped, the switch latches and is reset by a booted push-button. The XY2CH13250 has 1 NC + 1 NO and the XY2CH13270 2 NC slow-break contacts, with positive opening to EN/IEC 60947-5-1. With appropriate monitoring and correct wiring it can reach category 4, PL e (EN/ISO 13849-1) and SIL 3 (EN/IEC 61508).
The body is Zamak and the cover stainless steel; housing colour is red RAL 3000. There are three tapped entries for Pg 13.5 cable glands. Rated operational current is 3 A at 240 V in AC-15 and 0.27 A at 250 V in DC-13; thermal current is 10 A. Mechanical durability is 800,000 cycles and B10d is 4,000,000 to IEC 60947-5-5 for a 20-year life time. Net weight is 0.865 kg. Operating temperature is -25 to +70 °C, degree of protection IP65. It conforms to EN/ISO 13850 and EN/IEC 60947-5-5; UL (NISD) and CCC certified.
Telemecanique XY2CH technical specifications
| General | |
|---|---|
| Product type | Latching emergency stop rope pull switch |
| Product range | XY2C (XY2CH) |
| Reset | Booted push-button |
| Local signalling | Without pilot light |
| Safety ratings | |
| Performance level (PL) | Up to PL e with the appropriate monitoring system and correct wiring (EN/ISO 13849-1) |
| Safety category | Up to category 4 (EN/ISO 13849-1) |
| Safety integrity level (SIL) | Up to SIL 3 (EN/IEC 61508) |
| Positive opening | Yes (EN/IEC 60947-5-1) |
| B10d | 4,000,000 (for a life time of 20 years) |
| Electrical characteristics | |
| Contact operation | Slow-break |
| Rated insulation voltage (Ui) | 500 V, pollution degree 3 (EN/IEC 60947-1); 300 V (UL 508) |
| Rated operational current | AC-15 A300: 3 A at 240 V; DC-13 Q300: 0.27 A at 250 V |
| Conventional enclosed thermal current (Ithe) | 10 A |
| Rated impulse withstand voltage (Uimp) | 6 kV |
| Short-circuit protection | 10 A cartridge fuse, type gG (EN/IEC 60269) |
| Terminal clamping capacity | Screw clamp terminals, 1 × 0.5 mm² to 2 × 1.5 mm²; tightening torque 0.8–1.2 N·m |
| Mechanical and connection | |
| Trigger cable maximum length | 30 m |
| Distance between cable supports | 5 m |
| Trigger cable anchor point | RH or LH side |
| Cable entry | 3 tapped entries for Pg 13.5 cable gland |
| Housing material | Zamak body, stainless steel cover |
| Housing colour | Red RAL 3000 |
| Mechanical durability | 800,000 cycles |
| Net weight | 0.865 kg |
| Environmental | |
| Operating temperature | -25 to +70 °C |
| Vibration resistance | 10 gn, f = 10–150 Hz (EN/IEC 60068-2-6) |
| Shock resistance | 50 gn, 11 ms (EN/IEC 60068-2-27) |
| Electrical shock protection class | Class I (IEC 61140) |
| Degree of protection | IP65 (IEC 60529) |
| Certifications | UL (category NISD emergency stop devices), CCC |
Telemecanique XY2CH models
| Code | Contacts |
|---|---|
| XY2CH13250 | 1 NC + 1 NO |
| XY2CH13270 | 2 NC |
Key features
- Trigger cable up to 30 m, RH or LH anchoring
- Latches when tripped, reset by booted push-button
- 1 NC + 1 NO or 2 NC; positive opening of NC contacts
- Up to category 4, PL e and SIL 3 with appropriate monitoring
- Zamak body, stainless steel cover, red RAL 3000
- Conforms to EN/ISO 13850 and EN/IEC 60947-5-5; IP65
XY2CH ordering codes
| Part number | Description |
|---|---|
| XY2CH13250 | Latching emergency stop rope pull switch XY2CH, 1 NC + 1 NO, booted push-button |
| XY2CH13270 | Latching emergency stop rope pull switch XY2CH, 2 NC, booted push-button |
XY2CH accessories
Accessories listed by the manufacturer for this product (ordered separately):
| Part number | Description |
|---|---|
| XY2CZ301 | Red galvanised cable, Ø 3.2 mm, 10.5 m |
| XY2CZ3015 | Red galvanised cable, Ø 3.2 mm, 15.5 m |
| XY2CZ3020 | Red galvanised cable, Ø 3.2 mm, 20.5 m |
| XY2CZ302 | Red galvanised cable, Ø 3.2 mm, 25.5 m |
| XY2CZ303 | Red galvanised cable, Ø 3.2 mm, 30.5 m |
| XY2CZ9310 | Mounting kit, Ø 3.2 mm (for XY2CH) |
| XY2CZ9315 | Mounting kit, Ø 3.2 mm (for XY2CH) |
| XY2CZ9320 | Mounting kit, Ø 3.2 mm, L 20.5 m (for XY2CJ and XY2CH) |
| XY2CZ9330 | Mounting kit, Ø 3.2 mm (for XY2CH) |
| XY2CZ703 | End spring (for XY2CH) |
| XY2CZ705 | Pulley bracket |
| XY2CZ708 | Pulley, diameter 33 mm (for cable Ø 5 mm maximum) |
| XY2CZ601 | Fixed cable support |
| XY2CZ918 | Tensioner spring kit (spring, notched washer and circlip) |
Other Telemecanique Emergency Stop & Enabling Switches
- TELEMECANIQUE XY2CE — Emergency stop rope pull switch (trigger cable up to 70 m)
Models from other brands: Emergency Stop & Enabling Switches
Is this switch right for your application?
Share the machine to be stopped, the place of use (panel, along the line, handheld pendant), the contact configuration and the required performance level (PL); let’s select the right emergency stop or enabling switch together.
All product specifications are subject to change without notice. Validation of the safety function and the risk assessment remain the responsibility of the machine builder. Source: Telemecanique Sensors product data sheets (XY2CH13250_EN.pdf, XY2CH13270_EN.pdf, sheet date 30 July 2024; downloads.telemecaniquesensors.com/dam/datasheets/en/) and telemecaniquesensors.com/global/en/product/reference/ reference pages (accessed 25 September 2026).