TELEMECANIQUE XY2CE — Emergency Stop & Enabling Switches
Telemecanique XY2CE: latching emergency stop rope pull switch, trigger cable up to 70 m, 1 NC + 1 NO, RH or LH anchoring, IP66.

Status: In production
Brand: Telemecanique
Product: Emergency stop rope pull switch (trigger cable up to 70 m)
Trigger cable maximum length: 70 m
Contacts: 1 NC + 1 NO
Trigger cable anchor point: RH side (XY2CE1A250) or LH side (XY2CE2A250)
Performance level (PL): Up to PL e, SIL 3, category 4 (with appropriate monitoring)
Degree of protection: IP66
The Telemecanique XY2CE is a latching emergency stop rope pull switch from the XY2C range. It works with a single trigger cable up to 70 m long, with 5 m between cable supports. The cable anchor point is on the right-hand side on the XY2CE1A250 and on the left-hand side on the XY2CE2A250. When tripped, the switch latches and is reset by a booted push-button. Contacts are 1 NC + 1 NO, slow-break, with positive opening to EN/IEC 60947-5-1. With appropriate monitoring and correct wiring it can reach category 4, PL e (EN/ISO 13849-1) and SIL 3 (EN/IEC 61508).
The body is Zamak and the cover stainless steel; housing colour is red RAL 3000. There are three plain holes for Pg 13.5 or ISO M20 cable glands. Rated operational current is 3 A at 240 V in AC-15 and 0.27 A at 250 V in DC-13; thermal current is 10 A. Mechanical durability is 60,000 cycles and B10d is 300,000 to IEC 60947-5-5 for a 20-year life time. Net weight is 1.45 kg. Operating temperature is -25 to +70 °C, degree of protection IP66. It conforms to EN/ISO 13850 and EN/IEC 60947-5-5; UL (NISD), CSA and CCC certified.
Telemecanique XY2CE technical specifications
| General | |
|---|---|
| Product type | Latching emergency stop rope pull switch |
| Product range | XY2C (XY2CE) |
| Reset | Booted push-button |
| Local signalling | Without pilot light |
| Safety ratings | |
| Performance level (PL) | Up to PL e with the appropriate monitoring system and correct wiring (EN/ISO 13849-1) |
| Safety category | Up to category 4 (EN/ISO 13849-1) |
| Safety integrity level (SIL) | Up to SIL 3 (EN/IEC 61508) |
| Positive opening | Yes (EN/IEC 60947-5-1) |
| B10d | 300,000 (for a life time of 20 years) |
| Electrical characteristics | |
| Contacts | 1 NC + 1 NO |
| Contact operation | Slow-break |
| Rated insulation voltage (Ui) | 500 V, pollution degree 3 (EN/IEC 60947-1); 300 V (UL 508, CSA C22.2 No 14) |
| Rated operational current | AC-15 A300: 3 A at 240 V; DC-13 Q300: 0.27 A at 250 V |
| Conventional enclosed thermal current (Ithe) | 10 A |
| Short-circuit protection | 10 A cartridge fuse, type gG (EN/IEC 60269) |
| Terminal clamping capacity | Screw clamp terminals, 1 × 0.5 mm² to 2 × 1.5 mm²; tightening torque 0.8–1.2 N·m |
| Mechanical and connection | |
| Trigger cable maximum length | 70 m |
| Distance between cable supports | 5 m |
| Cable entry | 3 plain holes for Pg 13.5 or ISO M20 cable gland |
| Housing material | Zamak body, stainless steel cover |
| Housing colour | Red RAL 3000 |
| Mechanical durability | 60,000 cycles |
| Net weight | 1.45 kg |
| Environmental | |
| Operating temperature | -25 to +70 °C |
| Vibration resistance | 10 gn, f = 10–300 Hz (EN/IEC 60068-2-6) |
| Shock resistance | 50 gn, 11 ms (EN/IEC 60068-2-27) |
| Electrical shock protection class | Class I (IEC 61140) |
| Degree of protection | IP66 (IEC 60529) |
| Certifications | UL (category NISD emergency stop devices), CSA, CCC |
| Standards | EN/ISO 13850, EN/IEC 60947-5-5, EN/IEC 60947-5-1, EN/IEC 60204-1 |
Telemecanique XY2CE models
| Code | Trigger cable anchor point | Contacts |
|---|---|---|
| XY2CE1A250 | RH side | 1 NC + 1 NO |
| XY2CE2A250 | LH side | 1 NC + 1 NO |
Key features
- Trigger cable up to 70 m, 5 m between supports
- RH (1A250) or LH (2A250) cable anchoring
- Latches when tripped, reset by booted push-button
- 1 NC + 1 NO; positive opening of NC contact
- Up to category 4, PL e and SIL 3 with appropriate monitoring
- Zamak body, stainless steel cover; IP66
XY2CE ordering codes
| Part number | Description |
|---|---|
| XY2CE1A250 | Latching emergency stop rope pull switch XY2CE, RH side, 1 NC + 1 NO, booted push-button |
| XY2CE2A250 | Latching emergency stop rope pull switch XY2CE, LH side, 1 NC + 1 NO, booted push-button |
XY2CE accessories
Accessories listed by the manufacturer for this product (ordered separately):
| Part number | Description |
|---|---|
| XY2CZ1015 | Red galvanised cable, Ø 5 mm, 15.5 m (for XY2CB) |
| XY2CZ102 | Red galvanised cable, Ø 5 mm, 25.5 m (for XY2CB) |
| XY2CZ105 | Red galvanised cable, Ø 5 mm, 50.5 m (for XY2CB) |
| XY2CZ107 | Red galvanised cable, Ø 5 mm, 70.5 m (for XY2CE) |
| XY2CZ9525 | Mounting kit, Ø 5 mm (for XY2CE) |
| XY2CZ9550 | Mounting kit, Ø 5 mm (for XY2CE) |
| XY2CZ9570 | Mounting kit, Ø 5 mm (for XY2CE) |
| XY2CZ213 | Tensioner (for XY2CED and XY2CE) |
| XY2CZ702 | End spring (for XY2CE) |
| XY2CZ705 | Pulley bracket |
| XY2CZ708 | Pulley, diameter 33 mm (for cable Ø 5 mm maximum) |
| XY2CZ601 | Fixed cable support |
| XY2CZ404 | Turnbuckle M8 (for XY2CB) |
| XY2CZ800 | Pilot light head, red (for XY2CE) |
| XY2CZ801 | Pilot light head, orange (for XY2CE) |
Other Telemecanique Emergency Stop & Enabling Switches
- TELEMECANIQUE XY2CH — Emergency stop rope pull switch (trigger cable up to 30 m)
Models from other brands: Emergency Stop & Enabling Switches
Is this switch right for your application?
Share the machine to be stopped, the place of use (panel, along the line, handheld pendant), the contact configuration and the required performance level (PL); let’s select the right emergency stop or enabling switch together.
All product specifications are subject to change without notice. Validation of the safety function and the risk assessment remain the responsibility of the machine builder. Source: Telemecanique Sensors product data sheets (XY2CE1A250_EN.pdf, XY2CE2A250_EN.pdf, sheet date 30 July 2024; downloads.telemecaniquesensors.com/dam/datasheets/en/) and telemecaniquesensors.com/global/en/product/reference/ reference pages (accessed 25 September 2026).