TELEMECANIQUE XCKN — Limit Switches

Telemecanique XCKN: compact plastic limit switch, 1 NC + 1 NO snap action contacts, positive opening, M20 cable entry, IP65.

Telemecanique XCKN — Compact plastic limit switch (XC Standard)

Status: In production

Brand: Telemecanique

Product: Compact plastic limit switch (XC Standard)

Contacts: 1 NC + 1 NO, snap action

Positive opening: With

Cable entry: M20 x 1.5

IP degree of protection: IP65

Mechanical durability: 10 million cycles

Request a quote for price and stock

Telemecanique XCKN is the compact limit switch series of the XC Standard range with plastic body and plastic head. The series includes the XCKN2118P20 with rotary head and thermoplastic roller lever actuated by a 30° cam (compact form A), and the XCKN2110P20 with metal end plunger actuated on end (compact form B). Both models offer 1 NC + 1 NO snap action contacts, an NC contact with positive opening, screw-clamp terminals and a single M20 x 1.5 cable entry for cable outer diameters of 7 to 13 mm. Body width is 30 mm.

Contact ratings per IEC 60947-5-1 appendix A are A300 (AC-15, 240 V, 3 A, Ithe 10 A) and R300 (DC-13, 250 V, 0.1 A). Mechanical durability is 10 million cycles and DC-13 electrical durability is 5 million cycles. The enclosure provides IP65 and IK04 protection and electric shock protection class II. Operating temperature is -25 to 70 °C and storage temperature -40 to 70 °C. The products carry UL, CSA and CCC certifications and conform to IEC 60947-5-1, IEC 60204-1, UL 508 and CSA C22.2 No 14.

Telemecanique XCKN technical specifications

General
SeriesXC Standard, XCKN (standard format)
Body materialPlastic
Head materialPlastic
Body typeFixed
Safety ratings
Positive openingWith (NC contact, IEC 60947-5-1)
Electrical characteristics
Contacts1 NC + 1 NO
Contact operationSnap action
Utilisation category AC-15A300: Ue = 240 V, Ie = 3 A, Ithe 10 A
Utilisation category DC-13R300: Ue = 250 V, Ie = 0.1 A
Rated insulation voltage (Ui)500 V (pollution degree 3, IEC 60947-1); 300 V (UL 508, CSA C22.2 No 14)
Rated impulse withstand voltage (Uimp)6 kV (IEC 60664, IEC 60947-1)
Short-circuit protection10 A cartridge fuse, type gG
Electrical durability5 million cycles, DC-13 (IEC 60947-5-1 appendix C): 24 V / 10 W; 48 V / 7 W; 120 V / 4 W
Electrical connectionScrew-clamp terminals, 1 × 0.34 to 2 × 1.5 mm²
Cable entryOne entry tapped for M20 x 1.5 cable gland, cable outer diameter 7 to 13 mm
Mechanical and connection
Mechanical durability10 million cycles
Environmental
IP degree of protectionIP65 (IEC 60529)
IK degree of protectionIK04 (IEC 62262)
Shock resistance45 gn for 11 ms (IEC 60068-2-27)
Vibration resistance25 gn, 10 to 500 Hz (IEC 60068-2-6)
Electric shock protection class (IEC 61140)Class II
Operating temperature-25 to 70 °C
Storage temperature-40 to 70 °C
General
Product certificationsUL, CSA, CCC
StandardsIEC 60947-5-1, IEC 60204-1, UL 508, CSA C22.2 No 14

Telemecanique XCKN models

CodeHead / operatorDesignActuationPositive opening minimumMinimum for trippingMaximum speedDimensions (W × H × D)Weight
XCKN2118P20Rotary head, thermoplastic roller leverCompact form ABy 30° cam, lateral, two directions0.15 N.m0.1 N.m1.5 m/s30 × 108 × 44.5 mm0.175 kg
XCKN2110P20Plunger head, metal end plungerCompact form BOn end, vertical, one direction30 N15 N0.5 m/s30 × 75 × 30 mm0.135 kg

Key features

  • Plastic body and plastic head, 30 mm body width
  • 1 NC + 1 NO snap action contacts, positive opening on the NC contact
  • Single M20 x 1.5 cable entry (cable outer diameter 7 to 13 mm), screw-clamp terminals
  • IP65, IK04, electric shock protection class II
  • 10 million cycles mechanical durability
  • UL, CSA and CCC certifications

XCKN ordering codes

Part numberDescription
XCKN2118P20XCKN, thermoplastic roller lever, 1 NC + 1 NO, snap action, M20
XCKN2110P20XCKN, metal end plunger, 1 NC + 1 NO, snap action, M20

Other Telemecanique Limit Switches

Models from other brands: Limit Switches

Is this limit switch right for your application?

Share the motion to be detected (direction, speed, stroke), the required actuator (roller lever, plunger, rotary head), the contact configuration, the cable entry, ambient conditions and any safety requirement (positive opening); let’s select the right limit switch together.

Request a quote Back to Limit Switches

All product specifications are subject to change without notice. Source: Telemecanique Sensors product data sheets XCKN2118P20_EN.pdf, XCKN2110P20_EN.pdf (30 July 2024), downloads.telemecaniquesensors.com/dam/datasheets/en/ and reference pages at telemecaniquesensors.com/global/en/product/reference/ (accessed 25 September 2026).