TELEMECANIQUE XCKM — Limit Switches

Telemecanique XCKM: Zamak-body limit switch, 1 NC + 1 NO snap action contacts, positive opening, 3 cable entries, IP66, IK05.

Telemecanique XCKM — Metal-body classic limit switch (XC Standard, 3 cable entries)

Status: In production

Brand: Telemecanique

Product: Metal-body classic limit switch (XC Standard, 3 cable entries)

Contacts: 1 NC + 1 NO, snap action

Positive opening: With

Conventional enclosed thermal current (Ithe): 10 A

IP degree of protection: IP66

Dimensions (W × H × D): 64 × 64 × 30 mm

Request a quote for price and stock

Telemecanique XCKM is the XC Standard limit switch series with Zamak body, 64 × 64 × 30 mm dimensions and three tapped cable entries. The XCKM115H29 has a rotary head with a spring return thermoplastic roller lever and M20 x 1.5 entries (cable outer diameter 7 to 13 mm). The XCKM102 has a plunger head with a metal roller plunger and Pg 11 entries. Both models are actuated laterally from two directions by a 30° cam, have 1 NC + 1 NO snap action contacts with positive opening on the NC contact, and use screw-clamp terminals.

Contact ratings per IEC 60947-5-1 appendix A are A300 (AC-15, 240 V, 3 A) and Q300 (DC-13, 250 V, 0.27 A), with a conventional thermal current of 10 A. DC-13 electrical durability is 5 million cycles; mechanical durability is 15 million cycles for the XCKM115H29 and 20 million cycles for the XCKM102. Minimum actuation speed is 0.01 m/min. Protection is IP66 and IK05, with electric shock protection class I. Operating temperature is -25 to 70 °C. The products carry UL, CSA and CCC certifications.

Telemecanique XCKM technical specifications

General
SeriesXC Standard, XCKM (standard format)
Body materialZamak
Body typeFixed
Type of approachLateral approach, two directions
Switch actuationBy 30° cam
Safety ratings
Positive openingWith (NC contact, IEC 60947-5-1)
Electrical characteristics
Contacts1 NC + 1 NO
Contact operationSnap action
Utilisation category AC-15A300: Ue = 240 V, Ie = 3 A
Utilisation category DC-13Q300: Ue = 250 V, Ie = 0.27 A
Conventional enclosed thermal current (Ithe)10 A
Rated insulation voltage (Ui)500 V (pollution degree 3, IEC 60947-1); 300 V (UL 508, CSA C22.2 No 14)
Rated impulse withstand voltage (Uimp)6 kV (IEC 60664, IEC 60947-1)
Short-circuit protection10 A cartridge fuse, type gG
Electrical durability5 million cycles, DC-13 (IEC 60947-5-1 appendix C): 24 V / 7 W; 48 V / 10 W; 120 V / 4 W
Electrical connectionScrew-clamp terminals, 1 × 0.34 to 2 × 1.5 mm²
Mechanical and connection
Minimum actuation speed0.01 m/min
Dimensions (W × H × D)64 × 64 × 30 mm
Environmental
IP degree of protectionIP66 (IEC 60529)
IK degree of protectionIK05 (IEC 62262)
Shock resistance50 gn for 11 ms (IEC 60068-2-27)
Vibration resistance25 gn, 10 to 500 Hz (IEC 60068-2-6)
Electric shock protection class (IEC 61140)Class I
Operating temperature-25 to 70 °C
Storage temperature-40 to 70 °C
General
Product certificationsUL, CSA, CCC
StandardsIEC 60947-5-1, IEC 60204-1, UL 508, CSA C22.2 No 14

Telemecanique XCKM models

CodeHead / operatorCable entryPositive opening minimumMinimum for trippingMaximum speedMechanical durabilityWeight
XCKM115H29Rotary head, thermoplastic roller leverThree entries tapped for M20 x 1.5 cable gland, cable outer diameter 7 to 13 mm0.25 N.m0.1 N.m1.5 m/s15 million cycles0.28 kg
XCKM102Plunger head, metal roller plungerThree entries tapped for Pg 11 cable gland36 N12 N0.5 m/s20 million cycles0.255 kg

Key features

  • Zamak body, 64 × 64 × 30 mm
  • Three tapped cable entries (M20 x 1.5 or Pg 11)
  • 1 NC + 1 NO snap action contacts, positive opening on the NC contact
  • A300 / Q300 contact ratings, thermal current 10 A
  • IP66, IK05, electric shock protection class I
  • 15 to 20 million cycles mechanical durability (depending on model)

XCKM ordering codes

Part numberDescription
XCKM115H29XCKM, thermoplastic roller lever, 1 NC + 1 NO, snap action, 3 × M20
XCKM102XCKM, metal roller plunger, 1 NC + 1 NO, snap action, 3 × Pg 11

Other Telemecanique Limit Switches

Models from other brands: Limit Switches

Is this limit switch right for your application?

Share the motion to be detected (direction, speed, stroke), the required actuator (roller lever, plunger, rotary head), the contact configuration, the cable entry, ambient conditions and any safety requirement (positive opening); let’s select the right limit switch together.

Request a quote Back to Limit Switches

All product specifications are subject to change without notice. Source: Telemecanique Sensors product data sheets XCKM115H29_EN.pdf, XCKM102_EN.pdf (30 July 2024), downloads.telemecaniquesensors.com/dam/datasheets/en/ and reference pages at telemecaniquesensors.com/global/en/product/reference/ (accessed 25 September 2026).