PANASONIC SF-C10 — Safety Relays
Panasonic SF-C10: light curtain control unit, Category 4, PL e, 3 NO positively driven safety contacts, 10 ms response, SF-C11 / SF-C13.

Status: In production
Brand: Panasonic
Product: Control unit for safety light curtains (relay output)
Safety level: Category 4, PL e (ISO 13849-1:2015), Type 4 (IEC 61496-1)
Safety output: NO contact × 3, positively driven
Response time (ON→OFF): 10 ms or less
Supply: 24 V DC ±10 %, 100 mA or less
Models: SF-C11 (connector connection), SF-C13 (slim type, 22.5 mm)
The Panasonic SF-C10 series consists of exclusive control units for safety light curtains and shortens setup time for safety circuits. The SF-C11 plugs into the SF4D light curtain with an 8-core connector cable; the muting function cannot be used. The SF-C13 is a slim type only 22.5 mm thick that connects to Panasonic light curtains by discrete wire cable, and the muting function can be used. Both models are compatible up to Category 4 and support presses used in Japan together with SF4D-□-01. One model is set to match PNP or NPN light curtain output.
The safety output is three NO contacts (13-14, 23-24, 33-34); contacts are AgSnO, self-cleaning and positively driven. The SF-C11 is rated 30 V DC / 6 A and 230 V AC / 6 A, the SF-C13 30 V DC / 4 A and 230 V AC / 4 A. Response time is 10 ms or less; mechanical life is min. 10,000,000 and electrical life min. 100,000 operations. External relay monitoring and trailing edge functions are built in. The electronic fuse trips at 0.5 A and resets after power down. The enclosure is ABS, protection IP40 and terminals IP20.
Panasonic SF-C10 technical specifications
| General | |
|---|---|
| Applicable standards | EN / IEC 61496-1 (Type 4), EN ISO / ISO 13849-1:2015 (Category 4, PL e), EN 55011, JIS B 9704-1, JIS B 9705-1, ANSI/UL 61496-1, UL 1998 (Class 2) |
| Certifications | CE, UKCA, UL/c-UL Listing, TÜV SÜD |
| Connectable light curtains | SF-C11: SF4D series; SF-C13: safety light curtains by Panasonic Industry |
| Safety ratings | |
| B10d | minimum load 20,000,000, maximum load 400,000 |
| Mission time | 20 years |
| External relay monitor / trailing edge function | incorporated |
| Electrical characteristics | |
| Supply voltage / current consumption | 24 V DC ±10 %, ripple P-P 10 % or less / 100 mA or less (without light curtain) |
| Fuse | built-in electronic fuse, trips at 0.5 A or more, resets after power down |
| Polarity selection | SF-C11 by sliding switch, SF-C13 by cable connection; minus ground for PNP, plus ground for NPN light curtains |
| Outputs and indicators | |
| Safety output | NO contact × 3 (13-14, 23-24, 33-34), AC-15 / DC-13 (IEC 60947-5-1) |
| Rated voltage / current | SF-C11: 30 V DC / 6 A, 230 V AC / 6 A; SF-C13: 30 V DC / 4 A, 230 V AC / 4 A; min. load 10 mA (24 V DC) |
| Contact material | AgSnO, self-cleaning, positively driven |
| Response time | drop-out delay 10 ms or less; pick-up delay 80 ms (auto) / 90 ms (manual) or less |
| Mechanical / electrical life | min. 10,000,000 (180 per minute) / min. 100,000 operations (20 per minute, 230 V AC 3 A) |
| Auxiliary output | safety relay NC contact × 1 (41-42), 24 V DC / 2 A; semiconductor AUX PNP/NPN, max. 60 mA |
| Environmental | |
| Degree of protection | enclosure IP40, terminal IP20 |
| Operating temperature | -10 to +55 °C (no condensation or icing) |
| Storage temperature | -25 to +70 °C |
| Ambient humidity | 30–85 % RH (storage 30–95 % RH) |
| Vibration resistance | 10–55 Hz, 0.35 mm amplitude, X, Y and Z 20 times each |
| Mechanical and connection | |
| Connection terminal | SF-C11 detachable spring-cage terminal; SF-C13 spring-cage terminal |
| Enclosure material | ABS |
| Weight | SF-C11 approx. 320 g, SF-C13 approx. 200 g |
Panasonic SF-C10 models
| Model | Type | Light curtain connection | Muting | Contact rating | Contact protection fuse | Weight |
|---|---|---|---|---|---|---|
| SF-C11 | connector connection type | SF4D, 8-core connector cable (SFD-CB□, SFB-CCJ□) | not available | 6 A (30 V DC / 230 V AC) | 6 A | approx. 320 g |
| SF-C13 | slim type (22.5 mm) | discrete wire cable (SFD-CCB□, SFD-CC□ for SF4D) | available | 4 A (30 V DC / 230 V AC) | 4 A | approx. 200 g |
Key features
- SF-C11: plug-in connector connection shortens setup and replacement time
- SF-C11: removable spring-type terminal blocks with no torque control
- SF-C13: slim type only 22.5 mm thick, fits narrow panel spaces
- PNP/NPN polarity selection on all models
- 3 NO safety outputs with positively driven, self-cleaning AgSnO contacts
- Built-in electronic fuse that needs no replacement
SF-C10 ordering codes
| Part number | Description |
|---|---|
| SF-C11 | connector connection type control unit for SF4D, Category 4 (supports presses in Japan, not shearing machines) |
| SF-C13 | slim type control unit, discrete wire connection, muting available, Category 4 |
SF-C10 accessories
Accessories listed by the manufacturer for this product (ordered separately):
| Part number | Description |
|---|---|
| SFD-CB05 | SF4D bottom cap cable with connector, 8-core, 0.5 m (for SF-C11 connection) |
| SFB-CCJ3E | extension cable with connectors on both ends, emitter, 3 m (for SF-C11 connection) |
| SFB-CCJ3D | extension cable with connectors on both ends, receiver, 3 m (for SF-C11 connection) |
| SFD-CCB3 | SF4D bottom cap cable, discrete wire, 8-core, 3 m (for SF-C13 connection) |
| SFD-CC3 | SF4D extension cable with connector on one end, 3 m (for SF-C13 connection) |
Other Panasonic Safety Relays
- PANASONIC SF-C21 — Safety control unit (8 preset logics, PL e)
Models from other brands: Safety Relays
Is this safety relay right for your application?
Share the safety inputs to be connected (emergency stop, door switch, light curtain), the number of output contacts, the need for off-delayed outputs, the supply voltage and the required performance level (PL); let’s select the right unit together.
All product specifications are subject to change without notice. Validation of the safety function and the risk assessment remain the responsibility of the machine builder. Source: Panasonic Industry, https://industry.panasonic.com/global/en/products/fasys/sensor/safety/sf-c10, https://industry.panasonic.com/global/en/products/fasys/sensor/safety/number/sf-c11, https://industry.panasonic.com/global/en/products/fasys/sensor/safety/number/sf-c13 (accessed 25 September 2026).