TELEMECANIQUE XCSRC — Non-Contact Safety Switches
Telemecanique XCSRC: RFID contactless safety switch, PL e, SIL 3, category 4, 2 PNP safety outputs, Sao 10 mm, M12, IP69K.

Status: In production
Brand: Telemecanique
Product: Preventa RFID contactless safety switch (XCSRC)
Performance level (PL): PL e, category 4, SIL 3, SILCL 3
Safety outputs: 2 NO, solid-state PNP
Assured operating / release distance: 10 mm / 35 mm (face to face)
Rated supply voltage: 24 V DC (-20 to +10 %)
Degree of protection: IP65, IP66, IP67, IP69K
The Telemecanique XCSRC is a Preventa RFID contactless safety switch from the XCS range. In face-to-face mounting the assured operating distance (Sao) is 10 mm and the assured release distance (Sar) 35 mm; the transponder with rotary sensing face offers 3 approach directions. The family includes the standalone models XCSRC11MM12 (EDM and manual start, unique pairing) and XCSRC31AM12 (EDM and automatic start, re-pairing enabled), and the daisy-chain model XCSRC32M12 for series connection. It conforms to SIL 3 (IEC 61508), SILCL 3 (IEC 62061), PL e and category 4 (ISO 13849-1); PFHd is 5E-10/h.
The safety outputs are two solid-state PNP outputs (2 NO) with short-circuit protection. Supply is 24 V DC (-20 to +10 %, SELV or PELV) and current consumption 60 mA. Standalone models connect via one 8-pin M12 male connector, the daisy-chain model via two 5-pin M12 male connectors. Risk time is 120 ms; on the daisy-chain model 18 ms is added per additional switch connected in series. The housing material is Valox, with two multi-colour LEDs for status. Operating temperature is -25 to +70 °C, degree of protection IP65, IP66, IP67 and IP69K.
Telemecanique XCSRC technical specifications
| General | |
|---|---|
| Product type | RFID contactless safety switch |
| Product range | XCS (XCSRC), Preventa |
| Design | Rectangular, standard |
| Dimensions | Transponder: 50 × 15 × 15 mm |
| Safety ratings | |
| Safety integrity level (SIL) | SIL 3 (IEC 61508), SILCL 3 (IEC 62061) |
| Performance level (PL) | PL e (ISO 13849-1) |
| Safety category | Category 4 (ISO 13849-1) |
| PFHd | 5E-10/h (IEC 62061, ISO 13849-1) |
| Mission time | 20 years |
| Detection | |
| Assured operating distance (Sao) | 10 mm face to face |
| Assured release distance (Sar) | 35 mm face to face |
| Approach directions | 3 directions (transponder with rotary sensing face) |
| Electrical characteristics | |
| Rated supply voltage | 24 V DC (-20 to +10 %), SELV or PELV (IEC 60204-1) |
| Current consumption | 60 mA |
| Rated insulation voltage (Ui) | 30 V DC |
| Rated impulse withstand voltage (Uimp) | 0.8 kV (IEC 60947-5-2) |
| Outputs and indicators | |
| Safety outputs | 2 NO, solid-state PNP, short-circuit protected |
| Maximum switching voltage | 26.4 V DC |
| Switching frequency | Maximum 0.5 Hz |
| Maximum delay at first power-up | 5 s |
| Local signalling | 2 multi-colour LEDs (green, orange, red) |
| Mechanical and connection | |
| Housing material | Valox |
| Tightening torque | Less than 1.5 N·m |
| Environmental | |
| Operating temperature | -25 to +70 °C |
| Storage temperature | -40 to +85 °C |
| Vibration resistance | 10 gn, f = 10–150 Hz (IEC 60068-2-6) |
| Shock resistance | 30 gn for 11 ms (IEC 60068-2-27) |
| Electrical shock protection class | Class III (IEC 61140) |
| Degree of protection | IP65, IP66, IP67 (IEC 60529); IP69K (DIN 40050) |
| Certifications | TÜV, CSA 22-2, FCC, IC, RCM, E2, Ecolab |
Telemecanique XCSRC models
| Code | Model type | Start / EDM | Pairing | Electrical connection | Reader size | Switching capacity | Risk time | Response time |
|---|---|---|---|---|---|---|---|---|
| XCSRC11MM12 | Standalone | Manual start, EDM | Unique pairing | 1 × M12 male, 8-pin | 108.3 × 30 × 15 mm | 400 mA | 120 ms | 250 ms typical |
| XCSRC31AM12 | Standalone | Automatic start, EDM | Re-pairing enabled | 1 × M12 male, 8-pin | 108.3 × 30 × 15 mm | 400 mA | 120 ms | 250 ms typical |
| XCSRC32M12 | Daisy chain | Via external safety module | Re-pairing enabled | 2 × M12 male, 5-pin (input and output) | 119.6 × 30 × 15 mm | 200 mA | 120 ms + 18 ms per additional switch in series | 120 ms + 50 ms typical per additional switch in series |
Key features
- RFID coded contactless sensing, 3 approach directions
- SIL 3, SILCL 3, PL e and category 4; PFHd 5E-10/h
- 2 solid-state PNP safety outputs, short-circuit protected
- EDM with manual or automatic start on standalone models
- Series connection via M12 on the daisy-chain model
- IP65, IP66, IP67 and IP69K; Ecolab certification
XCSRC ordering codes
| Part number | Description |
|---|---|
| XCSRC11MM12 | RFID safety switch XCSRC, standalone model, EDM + manual start, unique pairing, M12 |
| XCSRC31AM12 | RFID safety switch XCSRC, standalone model, EDM + auto start, multiple pairing enabled, M12 |
| XCSRC32M12 | RFID safety switch XCSRC, daisy-chain model, multiple pairing enabled, M12 |
XCSRC accessories
Accessories listed by the manufacturer for this product (ordered separately):
| Part number | Description |
|---|---|
| XCSRZSRC1 | Reader fixing plate, steel |
| XCSRZSTK1 | Transducer fixing plate, steel (for XCSRK) |
| XCSRK2A3 | RFID transducer XCSRK, blank (for XCSRC3…) |
| XZCP11V12L2 | Pre-wired M12 female connector, straight, 5-pin, PUR cable, 2 m |
| XZCP12V12L2 | Pre-wired M12 female connector, elbowed (90°), 5-pin, PUR cable, 2 m |
| XZCP29P12L2 | Pre-wired M12 female connector, straight, 8-pin, PUR cable, 2 m (standalone models) |
| XCSRZE | Loopback device, M12 plug (for daisy-chain models) |
| XZCR1111064D3 | Series connection jumper, 2 straight M12 female, 5-pin, 3 m, PUR |
| XCSRD210MDB | Safety RFID diagnostic module, Modbus RTU (for daisy-chain models) |
Other Telemecanique Non-Contact Safety Switches
- TELEMECANIQUE XCSDMC — Coded magnetic safety switch, compact rectangular
- TELEMECANIQUE XCSDMP — Coded magnetic safety switch, standard rectangular
- TELEMECANIQUE XCSDMR5902 — Coded magnetic safety switch, cylindrical
Models from other brands: Non-Contact Safety Switches
Is this non-contact safety switch right for your application?
Share the door type, the mounting surface (metal/plastic), the coding requirement, the number of switches to be connected in series and your safety controller; let’s select the right switch and evaluation unit together.
All product specifications are subject to change without notice. Validation of the safety function and the risk assessment remain the responsibility of the machine builder. Source: Telemecanique Sensors product data sheets (XCSRC11MM12_EN.pdf, XCSRC31AM12_EN.pdf, XCSRC32M12_EN.pdf, sheet date 30 July 2024; downloads.telemecaniquesensors.com/dam/datasheets/en/) and telemecaniquesensors.com/global/en/product/reference/ reference pages (accessed 25 September 2026).