PANASONIC HL-G125 — Displacement Sensors

Panasonic HL-G125: compact laser displacement sensor, ±150 mm, resolution 20 μm, IP67.

Panasonic HL-G125 — Compact laser displacement sensor

Status: In production

Brand: Panasonic

Product: Compact laser displacement sensor

Series: HL-G1

Measuring: ±150 mm

Resolution: 20 μm

Light: Red semiconductor laser, Class 2 (IEC / EN / JIS / GB / KS)

Protection: IP67 (IEC)

Request a quote for price and stock

HL-G125 is a compact laser displacement sensor from Panasonic’s HL-G1 series: the amplifier is built into the sensor head, it measures the distance to the target at micron level by triangulation with a CMOS image sensor, shows the value on a 5-digit display and outputs it via analog output and three judgment outputs. Measurement center distance 250 mm, measurement range ±150 mm. Resolution: 20 μm. Linearity: ±0.3% F.S. Light source: Red semiconductor laser, Class 2 (IEC / EN / JIS / GB / KS), max. output 1 mW, 655 nm.

Sampling: 200 μs / 500 μs / 1 ms / 2 ms. Outputs: NPN / PNP open-collector (selectable), max. 50 mA. Analog voltage output: 0…+10.5 V. Analog current output: 3.2…20.8 mA. Supply: 24 V DC ±10 % including 0.5 V ripple (P-P). Degree of protection: IP67 (IEC). Ambient temperature: −10 to +45 °C (no condensation).

Panasonic HL-G125 technical specifications

HL-G125
General
ProductCompact laser displacement sensor
Regulations / certificationsCE, UKCA, FDA, KC (Korea)
Sensing
Measurement center distance250 mm
Measurement range±150 mm
Resolution20 μm
Linearity±0.3% F.S.
Temperature characteristics±0.08 % F.S./°C
Light sourceRed semiconductor laser, Class 2 (IEC / EN / JIS / GB / KS), max. output 1 mW, 655 nm
Beam diameter1.75 × 3.5 mm
Receiving elementCMOS image sensor
Sampling rate200 μs / 500 μs / 1 ms / 2 ms
Electrical characteristics
Supply voltage24 V DC ±10 % including 0.5 V ripple (P-P)
Current consumption100 mA or less
Output and indicators
Analog voltage output0…+10.5 V
Analog current output3.2…20.8 mA
Outputs (OUT 1–3)NPN / PNP open-collector (selectable), max. 50 mA
Digital display5-digit red LED display
Environmental
Pollution degree2
Operating altitude2,000 m or less
Degree of protectionIP67 (IEC)
Ambient temperature−10 to +45 °C (no condensation) · storage −20 to +60 °C
Ambient humidity35 to 85 % RH (storage 35 to 85 %)
Ambient illuminanceIncandescent light: 3,000 lx or less at the light-receiving face
Vibration resistance10 to 55 Hz, 1.5 mm double amplitude, X/Y/Z two hours each
Shock resistance500 m/s² (50 G approx.), X/Y/Z three times each
Mechanical and connection
MaterialEnclosure: PBT · Front cover: acrylic · Cable: PVC
Cable0.1 mm² 10-core cable, 5 m
WeightNet approx. 70 g (without cable) · Approx. 320 g (with cable) · Gross approx. 380 g

Key features

  • ±150 mm
  • resolution 20 μm
  • IP67
  • Linearity ±0.3% F.S.
  • Sampling 200 μs / 500 μs / 1 ms / 2 ms

HL-G125 ordering codes

Part numberDescription
HL-G125-A-C5Standard type, 5 m cable
HL-G125-S-JHigh functionality type (RS-422/485), 0.5 m cable with connector

HL-G1 accessories and related products

Accessories and related products listed by the manufacturer for this series (ordered separately):

Part numberDescription
HL-G1CCJ2Extension cable, 2 m (for high functionality type)
HL-G1CCJ5Extension cable, 5 m (for high functionality type)
HL-G1CCJ10Extension cable, 10 m (for high functionality type)
HL-G1CCJ20Extension cable, 20 m (for high functionality type)

Other models in the same series

All series: Displacement Sensors

Is this sensor right for your measurement application?

Share what you need to measure (distance, thickness, diameter, position), the required resolution/repeatability, the target material and surface, the mounting distance and your PLC interface (analog, IO-Link, EtherCAT, CC-Link, RS-485); let’s select the right measurement sensor together.

Request a quote Back to Displacement Sensors

All product specifications are subject to change without notice. Data compiled from the specification tables on Panasonic Industry’s industry.panasonic.com model and series pages (HL-G125-A-C5, HL-G125-S-J). For complete I/O signal conditions and function lists, refer to the manufacturer’s documents.