← Medium-high pixel series industrial camera
MV-CH240-10TM-C-NN

HIKROBOT MV-CH240-10TM-C-NN

24MP Area Scan Camera, IMX540, 10GigE, Mono, C-mount, fanless
Key Features
  • Resolution of 5328 × 4600, and pixel size of 2.74 μm × 2.74 μm.
  • Supports auto or manual adjustment of gain, exposure time, and manual adjustment of Gamma correction, LUT, etc.
  • Adopts 10 GigE interface, compatible with GigE, and max. transmission distance of 100 meters.
  • Compact design with mounting holes on panels for flexible mounting.
  • Compatible with GigE Vision V2.0 Protocol, GenlCam Standard, and third-party software based on the protocol and standard.
Detailed Parameters
Model
Product ModelMV-CH240-10TM-C-NN
Type24MP Area Scan Camera, IMX540, 10GigE, Mono, C-mount, fanless
Performance
Sensor TypeCMOS, global shutter
Sensor ModelSony® IMX540
Sensor Size1.2"
Pixel Size2.74 μm × 2.74 μm
Resolution5328 × 4600
Max. Frame Rate35.1 fps @ 5328 × 4600 Mono 8
Mono/ColorMono
Pixel FormatMono 8/10/10Packed/12/12Packed
Dynamic Range71 dB
SNR40 dB
Gain0 dB to 24 dB
Exposure TimeUltraShort exposure mode: 1 μs to 7 μs Standard exposure mode: 8 μs to 10 sec
Exposure ModeOff/Once/Continuous exposure mode
BinningSupports 1 × 1, 2 × 2
DecimationSupports 1 × 1, 1 × 2, 1 × 4, 2 × 1, 2 × 2, 2 × 4, 4 × 1, 4 × 2, 4 × 4
Reverse ImageSupports horizontal and vertical reverse image output
Electrical Features
Data Interface10 Gigabit Ethernet (10000 Mbit/s), compatible with Gigabit Ethernet (1000 Mbit/s)
Digital I/O12-pin P10 connector provides power and I/O, including opto-isolated input × 1 (Line 0), opto-isolated output × 1 (Line 1), bi-directional non-isolated I/O × 1 (Line 2), RS- 232 × 1
Power Supply9 VDC to 24 VDC
Power ConsumptionTyp. 10 W @ 12 VDC
Mechanical
Lens MountC-mount
Dimension84 mm × 84 mm × 92.5 mm (3.3" × 3.3" × 3.6")
WeightApprox. 600 g (1.3 lb)
Ingress ProtectionIP40 (under proper lens installation and wiring)
TemperatureWorking temperature: 0 °C to 50 °C (32 °F to 122 °F) Storage temperature: –30 °C to 70 °C (–22 °F to 158 °F)
Humidity20% RH to 95% RH (no condensation)
General
Client SoftwareMVS or third-party software meeting with GigE Vision Protocol
Operating System32/64-bit Windows 7/10, 64-bit Windows 11, and 32/64-bit Linux
CompatibilityGigE Vision V2.0, GenICam
CertificationCE, RoHS, KC