← Line Scan Camera
MV-CL044-91NC

HIKROBOT MV-CL044-91NC

4k 7μm, 2.5G, color
Key Features
  • Provides a transmission distance of up to 100 m without a repeater via the GigE interface.
  • Supports gain and exposure control, LUT, Gamma correction, etc.
  • Compact design for flexible installation.
  • Compatible with GigE Vision Protocol V2.0, GenlCam Standard, and third-party software based on the protocol and standard.
Detailed Parameters
Client SoftwareMVS or the third-party software meeting with GigE Vision protocol
Operating System32/64-bit Windows 7/10, 64-bit Windows 11 and 32/64-bit Linux
CompatibilityGigE Vision V2.0, GenICam
Sensor TypeCMOS
Pixel Size7 µm × 7 µm
Max. Line RateFull resolution: 75.3 kHz @ Mono 8/Bayer RG 8, 25.1 kHz @ RGB 8/BGR 8, 37.7 kHz @ Bayer RG 10 Line rate after ROI: Max. 100 kHz (3080 P and below)
Image ModeSupports 1-Line
Dynamic Range61.3 dB
SNR40.3 dB
Exposure Time1 μs to 10 ms
Exposure ModeOff/Once/Continuous exposure mode, and supports trigger-width exposure
Mono/ColorColor
Pixel FormatRGB 8, BGR 8 Bayer RG 8/10 Mono 8
BinningSupports 1 × 1, 1 × 2, 1 × 4, 2 × 1, 2 × 2, 2 × 4, 4 × 1, 4 × 2, 4 × 4
Reverse ImageNot supported
Trigger ModeExternal trigger, internal trigger
External Trigger ModeLine trigger, frame trigger, line + frame trigger
Data Interface2.5 Gigabit Ethernet (2500 Mbit/s), compatible with Gigabit Ethernet (1000 Mbit/s) and Fast Ethernet (100 Mbit/s)
Digital I/O12-pin P10 connector provides power and I/O: bi-directional configurable I/O × 4 (Line 0/1/3/4) and support single-ended/differential I/O signal
Power Supply12 VDC to 24 VDC, supports PoE
Power ConsumptionTyp. 7.2 W @ 12 VDC
Lens MountM42 *1.0, flange back length 12 mm Connecting to F-mount, C-mount, and other lenses via adapter ring
Dimension62 mm × 62 mm × 46.1 mm (2.4" × 2.4" × 1.8")
WeightApprox. 260 g (0.6 lb.)
Ingress ProtectionIP40 (under proper lens installation and wiring)
TemperatureWorking temperature: –20 °C to 55 °C (–4 °F to 131 °F) Storage temperature: –30 °C to 80 °C (–22 °F to 176 °F)
Humidity20% RH to 80% RH (no condensation)
CertificationCE, RoHS, KC
Datasheet