HIKROBOT MVL-MY-045-135C-MP — Lenses
HIKROBOT MVL-MY-045-135C-MP: telecentric lens, 0.45x magnification, 135±2 mm working distance, Φ11 mm.

The MVL-MY-045-135C-MP is a object-side telecentric lens designed for 0.45x magnification at a working distance of 135±2 mm; it is used with sensors up to Φ11 mm image size.
According to the manufacturer data, depth of field 6.24 mm, distortion ≤ 0.1%, object-side telecentricity ≤ 0.1°, object-side resolution 23 μm. Mount: C-Mount, with a coaxial light port.
Specifications
| 2/3″ Telecentric Lens | |
|---|---|
| Model | MVL-MY-045-135C-MP |
| Performance | |
| Magnification | 0.45x |
| Working distance | 135±2 mm |
| F-number | F15.8 |
| Image size | Φ11 mm |
| Optical distortion | ≤ 0.1% |
| Depth of field | 6.24 mm |
| Object-side resolution | 23 μm |
| Object-side telecentricity | ≤ 0.1° |
| Mechanical | |
| Mount | C-Mount |
| Dimensions | Φ34 mm × 123.8 mm |
| Weight | 150 g |
| Temperature | -10 ~ 50°C |
| Coaxial light port | Supported |
| General | |
| Certification | RoHS2.0 |
| Product identity | |
| HIKROBOT part no. | M000047628 |
| Status | Available |
Key features
- Object-side telecentric optics: changes in measured size with object distance are minimised.
- Magnification 0.45x, working distance 135±2 mm.
- Distortion ≤ 0.1%.
- Depth of field 6.24 mm.
- C-Mount, coaxial illumination port.
Where it is used
It is used in machine vision applications such as dimensional measurement and hole or edge position checks, where small changes in object distance must not affect the result.
Suitability depends on working distance, field of view, target characteristics and positioning. Selection is assessed on a per-project basis.
Other models in the series
Is this lens right for your application?
Let us determine focal length, sensor size, working distance and field of view together, based on your application. FST is HIKROBOT’s distributor in Türkiye; product selection, commissioning and after-sales support all come from one source.
The data herein may vary based on the environment, objects and other various factors, and HIKROBOT shall not assume the consequences arising therefrom.
Source: HIKROBOT product data