Product: Inductive proximity sensor, rectangular, top sensing

Max. operation distance (Sn): 2.5 mm

Output: NPN or PNP (-P), NO or NC

Connection: 1 m cable

Supply voltage: 12–24 V DC

Protection: IP68, IP68G

Request a quote for price and stock

Panasonic GX-H8 is a rectangular, top sensing GX-8 type inductive proximity sensor from the GX-F/H series. The maximum operation distance (Sn) is 2.5 mm ±8 % and the stable sensing range is 0 to 2.1 mm, referenced to an iron sheet of 15 × 15 × t 1 mm. Repeatability is 0.04 mm or less, hysteresis 20 % or less and maximum response frequency 500 Hz. The PBT enclosure has a polycarbonate/polyester indicator part; net weight is about 20 g.

Supply is 12 to 24 V DC (+10/−15 %, ripple 10 % or less); current consumption is 15 mA or less. GX-H8A is the NPN normally open model; B means normally closed, -P PNP output and I the different-frequency type. The output carries up to 100 mA with 2 V or less residual voltage and has no short-circuit protection. Protection is IP68 and IP68G; shock resistance is 10,000 m/s². The 1 m oil-, heat- and cold-resistant cable can be extended to 100 m in total with 0.3 mm² or thicker cable.

Panasonic GX-H8 technical specifications

General
TypeRectangular, top sensing, GX-8 type, GX-F/H series
Regulations and certificationsCE marking (EMC and RoHS directives), UKCA marking (EMC and RoHS regulations)
Detection
Max. operation distance (Sn)2.5 mm ±8 %
Stable sensing range (Sa)0 to 2.1 mm
Standard sensing objectIron sheet 15 × 15 × t 1 mm
Hysteresis20 % or less of operation distance
RepeatabilityAlong and perpendicular to sensing axis: 0.04 mm or less
Max. response frequency500 Hz
Temperature characteristicsWithin ±8 % of sensing range at +23 °C over -25 to +70 °C
Voltage characteristicsWithin ±2 % for +10/−15 % fluctuation of the supply voltage
Correction coefficient (non-ferrous metals)Iron 1; stainless steel (SUS304) approx. 0.76; brass approx. 0.50; aluminium approx. 0.48
Electrical characteristics
Supply voltage12 to 24 V DC +10/−15 %, ripple (p-p) 10 % or less
Current consumption15 mA or less
Short-circuit protectionNot incorporated (do not connect the output directly to a power supply or capacitive load)
Outputs and indicators
Output typeNPN open-collector transistor or PNP open-collector transistor (-P); utilization category DC-12 or DC-13
Maximum output current100 mA; applied voltage 30 V DC or less; residual voltage 2 V or less (at 100 mA)
Output operationA: normally open (NO), B: normally closed (NC); I: different-frequency type
Operation indicatorOrange LED (lights up when the output is ON)
Environmental
ProtectionIP68 (IEC), IP68G
Ambient temperature-25 to +70 °C; storage -40 to +85 °C
Vibration resistance10 to 500 Hz, 3 mm double amplitude (max. 20 G) in X, Y and Z directions for two hours each
Shock resistance10,000 m/s² (approx. 1,000 G) in X, Y and Z directions three times each
Voltage withstandability1,000 V AC for 1 min between all supply terminals and enclosure
Insulation resistance50 MΩ or more (500 V DC megger)
Mechanical and connection
MaterialEnclosure: PBT; indicator part: polycarbonate/polyester
Cable0.15 mm², 3-core oil-, heat- and cold-resistant cabtyre cable, 1 m; extendable up to 100 m in total with 0.3 mm² or thicker cable
Net weightApprox. 20 g
Close mounting0 mm between an I type and a non-I type (up to two sensors); for three or more, alternate the types with a minimum spacing of 6 mm
Tightening torque0.7 N·m or less; mounting hole ø3.4 mm

Key features

  • Rectangular housing, top sensing, Sn 2.5 mm
  • Variation at maximum operation distance within ±8 %; temperature characteristics ±8 %
  • Shock resistance 10,000 m/s², vibration resistance 10 to 500 Hz
  • IP68 and IP68G protective construction
  • Different-frequency I type allows two sensors to be mounted side by side
  • Metal sleeve prevents damage from over-tightening

GX-H8 ordering codes

Part numberDescription
GX-H8ANPN output, NO, 1 m cable
GX-H8AINPN output, NO, different-frequency type, 1 m cable
GX-H8BNPN output, NC, 1 m cable
GX-H8BINPN output, NC, different-frequency type, 1 m cable
GX-H8A-PPNP output, NO, 1 m cable
GX-H8AI-PPNP output, NO, different-frequency type, 1 m cable
GX-H8B-PPNP output, NC, 1 m cable
GX-H8BI-PPNP output, NC, different-frequency type, 1 m cable
GX-H8A-RNPN output, NO, bending-resistant cable
GX-H8A-C5NPN output, NO, 5 m cable
GX-H8A-P-RPNP output, NO, bending-resistant cable
GX-H8A-P-C5PNP output, NO, 5 m cable

GX-H8 accessories

Accessories listed by the manufacturer for this product (ordered separately):

Part numberDescription
MS-GXL8-4Mounting bracket for GX-8 type (M3 screw, nut and washers attached)
MS-GX8-1×10Mounting sleeve for GX-8 type, set of 10 (to reuse GXL-8 brackets)

Other Panasonic Rectangular Inductive Sensors

Models from other brands: Rectangular Inductive Sensors

Is this inductive sensor right for your application?

Share the metal target to be detected (material, size), the required sensing distance, the mounting type (flush / non-flush), ambient conditions (oil, coolant, washdown, temperature) and your PLC input (PNP/NPN, NO/NC); let’s select the right inductive sensor and connection cable together.

Request a quote Back to Rectangular Inductive Sensors

All product specifications are subject to change without notice. Source: Panasonic, GX-F/H series page (order guide, specifications, options, cautions for use) and GX-H8A, GX-H8A-P Spec Detail tables: https://industry.panasonic.com/global/en/products/fasys/sensor/proximity/gx-8, https://industry.panasonic.com/global/en/products/fasys/sensor/proximity/number/GX-H8A, https://industry.panasonic.com/global/en/products/fasys/sensor/proximity/number/GX-H8A-P (accessed 28 September 2026).