PANASONIC HL-G212B — Displacement Sensors
Panasonic HL-G212B: network-integrated laser displacement sensor, ±30 mm, resolution 4 μm, IP67.

Status: In production
Brand: Panasonic
Product: Network-integrated laser displacement sensor
Series: HL-G2
Measuring: ±30 mm
Resolution: 4 μm
Light: Red semiconductor laser, Class 2 (IEC / EN / JIS / GB / KS)
Protection: IP67 (IEC)
HL-G212B is a network-integrated laser displacement sensor from Panasonic’s HL-G2 series: the communication type (-S) carries Ethernet and RS-485 interfaces and an organic EL display on the sensor, while the analog output type (-A) delivers the measurement as an analog signal; it measures by diffuse reflection with a red semiconductor laser and CMOS image sensor. Measurement center distance 120 mm, measurement range ±30 mm. Resolution: 4 μm. Linearity (limited range): ±0.05 % F.S. (105 to 135 mm). Light source: Red semiconductor laser, Class 2 (IEC / EN / JIS / GB / KS), max. output 1 mW, 655 nm.
Sampling: 100 μs / 200 μs / 500 μs / 1 ms / 2 ms. Ethernet: 10BASE-T / 100BASE-TX (RJ45), auto negotiation; protocols: EtherNet/IP, Modbus TCP, SLMP. RS-485: 9,600/19,200/38,400/115,200/230,400 bps; Modbus RTU; up to 16 units. Supply: 24 V DC ±10 % (including ripple). Degree of protection: IP67 (IEC). Ambient temperature: −10 to +45 °C (no icing).
Panasonic HL-G212B technical specifications
| HL-G212B | |
|---|---|
| General | |
| Regulations / certifications | CE, FDA, TÜV SÜD (U.S.A., Canada), KC (Korea) |
| Sensing | |
| Measurement center distance | 120 mm |
| Measurement range | ±30 mm |
| Beam diameter | X-axis: approx. 100 μm · Y-axis: approx. 4,000 μm |
| Resolution | 4 μm |
| Linearity (limited range) | ±0.05 % F.S. (105 to 135 mm) |
| Linearity (other) | ±0.075 % F.S. |
| Temperature characteristics | ±0.03 % F.S./°C |
| Measuring method | Diffuse reflection |
| Light source | Red semiconductor laser, Class 2 (IEC / EN / JIS / GB / KS), max. output 1 mW, 655 nm |
| Receiving element | CMOS image sensor |
| Sampling rate | 100 μs / 200 μs / 500 μs / 1 ms / 2 ms |
| Electrical characteristics | |
| Supply voltage | 24 V DC ±10 % (including ripple) |
| Current consumption | 150 mA or less |
| Output and indicators | |
| Communication: Ethernet | 10BASE-T / 100BASE-TX (RJ45), auto negotiation; protocols: EtherNet/IP, Modbus TCP, SLMP |
| Communication: RS-485 | 9,600/19,200/38,400/115,200/230,400 bps; Modbus RTU; up to 16 units |
| Environmental | |
| Pollution degree | 2 |
| Operating altitude | 2,000 m or less |
| Grounding method | Capacitor grounding |
| Degree of protection | IP67 (IEC) |
| Ambient temperature | −10 to +45 °C (no icing) · storage −20 to +60 °C |
| Ambient humidity | 35 to 85 % RH (storage 35 to 85 %) |
| Ambient illuminance | Incandescent light: 3,000 lx or less at the light-receiving face |
| Vibration resistance | 10 to 55 Hz, 1.5 mm double amplitude, X/Y/Z two hours each |
| Shock resistance | 500 m/s² (50 G approx.), X/Y/Z three times each |
| Mechanical and connection | |
| Material | Product casing: aluminum die casting · Front cover: glass · Cable: PVC |
| Weight | Net approx. 150 g · Gross approx. 200 g |
Key features
- ±30 mm
- resolution 4 μm
- IP67
- Linearity ±0.05 % F.S. (105 to 135 mm)
- Sampling 100 μs / 200 μs / 500 μs / 1 ms / 2 ms
HL-G212B ordering codes
| Part number | Description |
|---|---|
| HL-G212B-S-MK | Communication type (Ethernet + RS-485, OLED display); beam X-axis: approx. 100 μm · Y-axis: approx. 4,000 μm |
| HL-G212B-A-MK | Analog output type; beam X-axis: approx. 100 μm · Y-axis: approx. 4,000 μm |
HL-G2 accessories and related products
Accessories and related products listed by the manufacturer for this series (ordered separately):
| Part number | Description |
|---|---|
| CN-8E-C2 | Ethernet cable, 2 m |
| CN-8E-C5 | Ethernet cable, 5 m |
| CN-8R-C2 | RS-485 cable, 2 m |
| CN-8R-C5 | RS-485 cable, 5 m |
| CN-8R-C10 | RS-485 cable, 10 m |
| CN-8R-C20 | RS-485 cable, 20 m |
| CN-8A-C2 | Analog output cable, 2 m |
| CN-8A-C5 | Analog output cable, 5 m |
Other models in the same series
- PANASONIC HL-G203B — Network-integrated laser displacement sensor
- PANASONIC HL-G205B — Network-integrated laser displacement sensor
- PANASONIC HL-G208B — Network-integrated laser displacement sensor
- PANASONIC HL-G225B — Network-integrated laser displacement sensor
All series: Displacement Sensors
Is this sensor right for your measurement application?
Share what you need to measure (distance, thickness, diameter, position), the required resolution/repeatability, the target material and surface, the mounting distance and your PLC interface (analog, IO-Link, EtherCAT, CC-Link, RS-485); let’s select the right measurement sensor together.
All product specifications are subject to change without notice. Data compiled from the specification tables on Panasonic Industry’s industry.panasonic.com model and series pages (HL-G212B-S-MK, HL-G212B-A-MK). For complete I/O signal conditions and function lists, refer to the manufacturer’s documents.