PANASONIC HL-G205B — Displacement Sensors

Panasonic HL-G205B: network-integrated laser displacement sensor, ±10 mm, resolution 1.5 μm, IP67.

Panasonic HL-G205B — Network-integrated laser displacement sensor

Status: In production

Brand: Panasonic

Product: Network-integrated laser displacement sensor

Series: HL-G2

Measuring: ±10 mm

Resolution: 1.5 μm

Light: Red semiconductor laser, Class 2 (IEC / EN / JIS / GB / KS)

Protection: IP67 (IEC)

Request a quote for price and stock

HL-G205B is a network-integrated laser displacement sensor from Panasonic’s HL-G2 series: the communication type (-S) carries Ethernet and RS-485 interfaces and an organic EL display on the sensor, while the analog output type (-A) delivers the measurement as an analog signal; it measures by diffuse reflection with a red semiconductor laser and CMOS image sensor. Measurement center distance 50 mm, measurement range ±10 mm. Resolution: 1.5 μm. Linearity (limited range): ±0.05 % F.S. (45 to 55 mm). Light source: Red semiconductor laser, Class 2 (IEC / EN / JIS / GB / KS), max. output 1 mW, 655 nm.

Sampling: 100 μs / 200 μs / 500 μs / 1 ms / 2 ms. Ethernet: 10BASE-T / 100BASE-TX (RJ45), auto negotiation; protocols: EtherNet/IP, Modbus TCP, SLMP. RS-485: 9,600/19,200/38,400/115,200/230,400 bps; Modbus RTU; up to 16 units. Supply: 24 V DC ±10 % (including ripple). Degree of protection: IP67 (IEC). Ambient temperature: −10 to +45 °C (no icing).

Panasonic HL-G205B technical specifications

HL-G205B
General
Regulations / certificationsCE, FDA, TÜV SÜD (U.S.A., Canada), KC (Korea)
Sensing
Measurement center distance50 mm
Measurement range±10 mm
Beam diameterX-axis: approx. 60 μm · Y-axis: approx. 2,000 μm
Resolution1.5 μm
Linearity (limited range)±0.05 % F.S. (45 to 55 mm)
Linearity (other)±0.075 % F.S.
Temperature characteristics±0.03 % F.S./°C
Measuring methodDiffuse reflection
Light sourceRed semiconductor laser, Class 2 (IEC / EN / JIS / GB / KS), max. output 1 mW, 655 nm
Receiving elementCMOS image sensor
Sampling rate100 μs / 200 μs / 500 μs / 1 ms / 2 ms
Electrical characteristics
Supply voltage24 V DC ±10 % (including ripple)
Current consumption150 mA or less
Output and indicators
Communication: Ethernet10BASE-T / 100BASE-TX (RJ45), auto negotiation; protocols: EtherNet/IP, Modbus TCP, SLMP
Communication: RS-4859,600/19,200/38,400/115,200/230,400 bps; Modbus RTU; up to 16 units
Environmental
Pollution degree2
Operating altitude2,000 m or less
Grounding methodCapacitor grounding
Degree of protectionIP67 (IEC)
Ambient temperature−10 to +45 °C (no icing) · storage −20 to +60 °C
Ambient humidity35 to 85 % RH (storage 35 to 85 %)
Ambient illuminanceIncandescent light: 3,000 lx or less at the light-receiving face
Vibration resistance10 to 55 Hz, 1.5 mm double amplitude, X/Y/Z two hours each
Shock resistance500 m/s² (50 G approx.), X/Y/Z three times each
Mechanical and connection
MaterialProduct casing: aluminum die casting · Front cover: glass · Cable: PVC
WeightNet approx. 150 g · Gross approx. 200 g

Key features

  • ±10 mm
  • resolution 1.5 μm
  • IP67
  • Linearity ±0.05 % F.S. (45 to 55 mm)
  • Sampling 100 μs / 200 μs / 500 μs / 1 ms / 2 ms

HL-G205B ordering codes

Part numberDescription
HL-G205B-S-MKCommunication type (Ethernet + RS-485, OLED display); beam X-axis: approx. 60 μm · Y-axis: approx. 2,000 μm
HL-G205B-A-MKAnalog output type; beam X-axis: approx. 60 μm · Y-axis: approx. 2,000 μm
HL-G205B-A-SKAnalog output type; beam approx. Ø60 μm
HL-G205B-S-SKCommunication type (Ethernet + RS-485, OLED display); beam approx. Ø60 μm

HL-G2 accessories and related products

Accessories and related products listed by the manufacturer for this series (ordered separately):

Part numberDescription
CN-8E-C2Ethernet cable, 2 m
CN-8E-C5Ethernet cable, 5 m
CN-8R-C2RS-485 cable, 2 m
CN-8R-C5RS-485 cable, 5 m
CN-8R-C10RS-485 cable, 10 m
CN-8R-C20RS-485 cable, 20 m
CN-8A-C2Analog output cable, 2 m
CN-8A-C5Analog output cable, 5 m

Other models in the same series

All series: Displacement Sensors

Is this sensor right for your measurement application?

Share what you need to measure (distance, thickness, diameter, position), the required resolution/repeatability, the target material and surface, the mounting distance and your PLC interface (analog, IO-Link, EtherCAT, CC-Link, RS-485); let’s select the right measurement sensor together.

Request a quote Back to Displacement Sensors

All product specifications are subject to change without notice. Data compiled from the specification tables on Panasonic Industry’s industry.panasonic.com model and series pages (HL-G205B-S-MK, HL-G205B-A-MK, HL-G205B-A-SK, HL-G205B-S-SK). For complete I/O signal conditions and function lists, refer to the manufacturer’s documents.