TELEMECANIQUE XS612B1PAL2 — Flush Cylindrical Inductive Sensors

Telemecanique XS612B1PAL2: Inductive proximity sensor, M12, flush, Sn 4 mm, PNP 1 NO, 2 m cable, 12–48 V DC.

Telemecanique XS612B1PAL2 — Inductive proximity sensor, M12, flush

Status: In production

Brand: Telemecanique

Product: Inductive proximity sensor, M12, flush

Sensing distance (Sn): 4 mm

Output: PNP, 1 NO

Connection: 2 m cable

Supply: 12–48 V DC

Degree of protection: IP68, IP69K

Request a quote for price and stock

The Telemecanique XS612B1PAL2 is an XS6-family inductive proximity sensor of the XS range with a cylindrical M12 x 1 threaded body. It is flush mountable in metal. Nominal sensing distance (Sn) is 4 mm, with an operating zone of 0–3.2 mm. Enclosure is nickel-plated brass, sensing face PPS; length 54 mm, threaded length 42 mm, net weight 0.075 kg. Differential travel is 1–15 % of the effective sensing distance; switching frequency is up to 2500 Hz. The manufacturer lists mobile equipment as its device application.

Supply is 12–48 V DC (limits 10–58 V DC) with reverse polarity protection. The PNP 1 NO output switches up to 200 mA with overload and short-circuit protection; closed-state voltage drop is below 2 V and no-load current consumption is at most 10 mA. Connection is via a 2 m PVC-insulated 3 x 0.34 mm² cable; a yellow LED shows the output state. Degree of protection is IP68 double insulation (IEC 60529) and IP69K (DIN 40050); operating temperature is -25 to +70 °C. Certifications: UL, E2 and CSA.

Telemecanique XS612B1PAL2 technical specifications

General
SeriesXS6, general purpose
Body designCylindrical, M12 x 1 thread
MountingFlush mountable
Detection
Nominal sensing distance (Sn)4 mm
Operating zone (Sa)0–3.2 mm
Differential travel1–15 % of effective sensing distance (Sr)
Switching frequency≤ 2500 Hz
Electrical characteristics
Rated supply voltage12–48 V DC with reverse polarity protection
Supply voltage limits10–58 V DC
Current consumption (no-load)≤ 10 mA
Voltage drop (closed state)Below 2 V
Delays (maximum)First-up 10 ms; response 0.2 ms; recovery 0.2 ms
Outputs and indicators
Output typePNP, 1 NO, DC
Wiring technique3-wire
Switching capacity≤ 200 mA with overload and short-circuit protection
Status LEDOutput state: 1 yellow LED
Mechanical and connection
Electrical connection2 m cable
Cable3 x 0.34 mm², PVC insulation
Enclosure materialnickel-plated brass
Sensing face materialPPS
Length / threaded length54 mm / 42 mm
Net weight0.075 kg
Minimum mounting distancesSide by side ≥ 8 mm; face to face ≥ 48 mm; facing a metal object ≥ 12 mm
Environmental
Degree of protectionIP68 double insulation (IEC 60529), IP69K (DIN 40050)
Operating temperature-25 to +70 °C
Storage temperature-40 to +85 °C
Vibration resistance25 gn, amplitude ±2 mm (f = 10–55 Hz), IEC 60068-2-6
Shock resistance50 gn for 11 ms, IEC 60068-2-27
Marking and certificationsCE; UL, E2, CSA

Key features

  • Sn 4 mm, flush mountable, M12 x 1 thread
  • PNP 1 NO output, up to 200 mA, overload and short-circuit protected
  • 12–48 V DC supply with reverse polarity protection
  • Nickel-plated brass enclosure, PPS sensing face
  • Degree of protection IP68, IP69K
  • 2 m PVC cable, yellow status LED

XS612B1PAL2 ordering codes

Part numberDescription
XS612B1PAL2PNP, 1 NO, 2 m cable
XS612B1PAM12PNP, 1 NO, M12 connector
XS612B1NAL2NPN, 1 NO, 2 m cable
XS612B1NAM12NPN, 1 NO, M12 connector
XS612B1PBL2PNP, 1 NC, 2 m cable
XS612B1PBM12PNP, 1 NC, M12 connector
XS612B1NBL2NPN, 1 NC, 2 m cable
XS612B1NBM12NPN, 1 NC, M12 connector

XS612B1PAL2 accessories

Accessories listed by the manufacturer for this product (ordered separately):

Part numberDescription
XSZB112Fixing clamp for Ø12 mm XS inductive sensors, plastic, with indexing
XSZBS12Mounting bracket for Ø12 mm XS inductive sensors, stainless steel

Other Telemecanique Flush Cylindrical Inductive Sensors

Models from other brands: Flush Cylindrical Inductive Sensors

Is this inductive sensor right for your application?

Share the metal target to be detected (material, size), the required sensing distance, the mounting type (flush / non-flush), ambient conditions (oil, coolant, washdown, temperature) and your PLC input (PNP/NPN, NO/NC); let’s select the right inductive sensor and connection cable together.

Request a quote Back to Flush Cylindrical Inductive Sensors

All product specifications are subject to change without notice. Source: Telemecanique Sensors, XS612B1PAL2 product data sheet (https://downloads.telemecaniquesensors.com/dam/datasheets/en/XS612B1PAL2_EN.pdf, 30 July 2024); reference page https://www.telemecaniquesensors.com/global/en/product/reference/XS612B1PAL2; XS catalogue TESEBRO000040EN (accessed 28 September 2026).