Safety Module for Light Curtain Muting (Preventa XPSLC Series) XPSLCMUT1160
The XPSLCMUT1160 is a dedicated Preventa safety module that manages the muting function of type 2 and type 4 safety light curtains, temporarily bypassing the light curtain's safety function during a defined, monitored material-pass window (e.g., pallet or conveyor pass-through) while keeping the machine protected the rest of the time. It is the muting-control counterpart to the safety light curtains already carried on the site, and is still commercialized under the Telemecanique Sensors (Yageo) brand as well as on Schneider Electric's se.com.
- Dedicated monitoring/control module for muting of type 2 and type 4 safety light curtains
- Compatible with through-beam and polarized/reflex photoelectric muting sensors
- 6 status LEDs for local diagnostics
- 24 V DC supply, screw terminals, 35 mm DIN rail mounting
- B10d reliability data: 800,000 operations
- IP2X protection rating
| Safety Category / PL Level (ISO 13849-1) | Category 4 / PL e (with correctly wired control system) |
| SIL / SILCL | SILCL 3 (IEC 62061); PFHd = 6.42E-9…5.03E-8 1/h |
| Function | Muting (temporary bypass) for type 2/4 safety light curtains |
| Response Time on Input Open | 20 ms |
| Supply Voltage | 24 V DC (-20/+20%) |
| Power Consumption | 5 W |
| Mounting / Terminals | 35 mm DIN rail, screw terminals |
| Certifications | cULus, TUV; IP2X (IEC 60529); standards IEC 62061 / ISO 13849-1 |