Harmony XPSU Safety Module (Preventa XPS Universal Series) — Emergency Stop / Safety Input Monitoring Relay XPSUAF13AP
XPSUAF13AP is the current Preventa/Harmony XPS Universal safety relay module used to monitor emergency-stop pushbuttons, safety switches, guard interlocks and other single-function safety inputs. It is the officially documented active replacement for the discontinued Preventa XPS emergency-stop relay XPSAF5130. The module provides more than 40 diagnostic messages without needing an additional fieldbus interface, and reports remaining service life/test-interval status to reduce unplanned downtime.
- More than 40 different diagnostic messages, without additional fieldbus interface
- Status information on upcoming test intervals and remaining cycles before end of life
- 2 NC safety inputs plus NO/NC contacts and 2 PNP solid-state diagnostic outputs
- 24 V AC or DC supply, screw terminal connections
- ECODESIGN optimized: 24% CO2 reduction over the product life cycle vs. predecessor
- Officially listed as the direct replacement for the discontinued XPSAF5130 Preventa XPS relay
| Safety Category / PL Level (ISO 13849-1) | Category 4 / PL e |
| SIL / SILCL | SIL 3 (IEC 61508) / SILCL 3 (IEC 62061) |
| Inputs / Outputs | 2 safety inputs; 3 N.O. + 1 N.C. safety relay outputs; 1 PNP solid-state diagnostic output |
| Response Time | < 20 ms |
| Supply Voltage | 24 V AC or DC |
| Mounting / Terminals | 35 mm DIN rail, screw terminals |
| Contact Rating | 6 A at 250 VAC / 24 VDC |
| Certifications | TUV, cULus |